C
HAPTER
2
8
ISO Product Controller II and Hawkeye Operation Manual
HAWKEYE
®
FEATURES
OPERATION MODES
The Hawkeye
®
control system can be configured in several different modes to fit the application.
TABLE 1. Operation Mode Features
• Standard - The Hawkeye
®
system will control to a target flow rate and target pressure. This is the most
common sprayer setting.
• Variable Pressure (VP) - This mode will control to a target-flow rate and target nozzle duty cycle by varying the
pressure. This is useful for scenarios where pressure is not a priority (i.e. fertilizer application).
• High Flow - This mode allows both a conventional nozzle and a Hawkeye
®
nozzle to run simultaneously to
achieve higher flow rates.
• On/Off - The Hawkeye
®
System will hold the nozzle valve 100% open during application or fully closed when
not applying. This mode can be used with air induction tips and stream bars.
• Bypass (Conventional) - The Hawkeye
®
system will control to a target flow, but the nozzle control valve is
disabled. A secondary flow outlet must be made available at each tip.Flow Control
• Conventional flow control spray systems use a flowmeter to monitor the flow through the flow through the
system and adjust a control valve to maintain target application rate. This allows the operator to turn on and off
sections and change vehicle speeds while maintaining the desired application rate.
PRESSURE NOZZLE CONTROL
The Hawkeye
®
nozzle control system provides the same spray pattern and coverage as conventional spray
systems. Pressure based nozzle control allows the operator to maintain the same target pressure and operate over
a larger application speed or flow range while maintaining droplet size. This may help manage spray drift and
allow the equipment to operate in higher winds. Better droplet control also provides more accurate field
application and better rate control at lower target flow rates than the flowmeter can detect.
TURN COMPENSATION
Conventional application systems provide a uniform rate across the boom or implement width. This functionality
works well in large field areas with straight swaths to ensure even coverage during application.
Standard
VP
High
Flow
On/Off
Bypass
Flow Control
Yes
Yes
Yes
Yes
Yes
Pressure Control
Yes
No
Yes
No
No
Turn Compensation
Yes
Yes
Yes
No
No
Individual Nozzle
Control
Yes
Yes
No
Yes
No
Virtual Sections
Yes
Yes
No
Yes
No
Wheel Tracks
Yes
Yes
Yes
No
No
Direct Injection
Yes
Yes
Yes
Yes
Yes
Summary of Contents for ISO Product Controller II
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Page 111: ...P N 016 0171 584 H 101...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...