Chapter 4
42
Willmar Eagle 8500 AutoBoom Installation Manual
FIGURE 19.
Machine’s Boom Function Coils
11.
Locate the machine’s boom function coils on the machine’s hydraulic valve.
12.
Locate the left tilt up coil.
13.
Determine which wire feeding into the coil receives the signal from the switches in the cab by pressing the
switch and using a test light or multi-meter to 12 volts.
14.
Locate the Left Solenoid Sense Up connector on the AutoBoom harness cable (P/N 115-0230-045 or 115-
0230-085).
15.
Use a 16-18 gauge scotch lock parallel splice connector (p/N 405-2001-079) to connect the left tilt up coil
wire to the Left Solenoid Sense Up connector.
16.
Locate the left tilt down coil.
17.
Determine which wire feeding into the coil receives the signal from the switches in the cab by pressing the
switch and using a test light or multi-meter to 12 volts.
18.
Locate the Left Solenoid Sense Down connector on the AutoBoom harness cable.
19.
Use a 16-18 gauge scotch lock parallel splice connector (P/N 405-2001-079) to connect the left tilt down coil
wire to the Left Solenoid Sense Down connector.
20.
Repeat the steps above to connect the right tilt up and down coils to the Right Solenoid Sense Up and
Down connectors on the AutoBoom harness cable.
Connect the Harness Cable to the Implement Extension Tee -
Gen II Cable Only
1.
Route the harness cable (P/N 115-0230-085) toward the implement extension tee cable.
2.
Connect the harness cable to the To Node connector.
3.
Remove the terminator from the machine’s chassis harness or the standalone console harness.
4.
Install the terminator on the remaining open end of the implement extension tee cable.
5.
Refer to the wiring schematic (beginning on page 44) appropriate for the machine’s configuration to route
the implement extension tee cable.
6.
Connect the implement extension tee cable to the location determined in the step above.
Connect the Harness Cable to the Controller Cable - Gen I
Cable Only
1.
Route the harness cable (P/N 115-0230-045) toward the machine’s cab.
2.
Connect the harness cable to the controller cable (P/N 115-0230-007).
Summary of Contents for AutoBoom Willmar Eagle 8500
Page 1: ...AutoBoom Installation Manual Willmar Eagle 8500 ...
Page 6: ...Table of Contents iv Willmar Eagle 8500 AutoBoom Installation Manual ...
Page 11: ...2 Manual No 016 0230 014 5 Introduction JIC fitting M ORFS fitting SAE O ring fitting ...
Page 12: ...Chapter 2 6 Willmar Eagle 8500 AutoBoom Installation Manual ...
Page 24: ...Chapter 3 18 Willmar Eagle 8500 AutoBoom Installation Manual Hydraulic Schematic ...
Page 29: ...3 Manual No 016 0230 014 23 PowerGlide PowerGlide Wiring Schematic ...
Page 30: ...Chapter 3 24 Willmar Eagle 8500 AutoBoom Installation Manual ...
Page 44: ...Chapter 4 38 Willmar Eagle 8500 AutoBoom Installation Manual Hydraulic Schematic ...
Page 51: ...4 Manual No 016 0230 014 45 PowerGlide Plus Gen II Cabling ...
Page 52: ...Chapter 4 46 Willmar Eagle 8500 AutoBoom Installation Manual ...
Page 65: ...5 Manual No 016 0230 014 59 UltraGlide Hydraulic Schematic ...
Page 73: ...Manual No 016 0230 014 67 UltraGlide UltraGlide Wiring Schematic Gen I Cabling ...
Page 74: ...Chapter 5 68 Willmar Eagle 8500 AutoBoom Installation Manual Gen II Cabling ...
Page 77: ...6 Manual No 016 0230 014 71 Replacement Parts Sensors ...
Page 78: ...Chapter 6 72 Willmar Eagle 8500 AutoBoom Installation Manual ...