Use and maintenance manual
HRV 180 PLUS
Rev.2 04/12/2020
EN
Pag.24
Description of the commands and symbols of the display
The innovation of this particular display consists of communication via waves channelled via low voltage (12 volts) between the
electronic board and the display. Communication occurs via a bipolar cable (e.g.: stereo speaker cable) and this is a novel idea
because it allows the display to be installed on a wall via an optional frame standardised for electric boxes 503.
N.B.: The symbol of the cleaner is active only on the stove models with an automatic cleaner system.
Button “1”
: button to access “Set room temp. - Set hot water temp.“ and regulation with keys 1 and 2.
Button “2”
: button to access “Set power“ and regulation with keys 1 and 2 (only powers which can be set are Min and Max)
“OK” button:
- quickly press this button to confirm the temperatures set;
- from the screen in Figure 15-A/B, quickly press the button to access the user menu;
- also from the screen of Figure 15-A/B, press the button for 3 seconds to switch on and off the stove.
The functionalities of this display when used in “BASE” mode are:
- switching stove on and off;
- room temperature setting and selection of the type of probe (probe supplied and connected to board or display integrated probe);
- hot water temperature setting;
- working power setting (Min - Max).
Switching stove on and off
Before switching on the stove for the first time, follow the procedure below:
1. Insert the power supply cable.
2. Position the switch on the back of the stove to position 1.
3. Check the system is connected to the flue.
4. Load the tank with 6 mm pellets.
6. Load the screw as described in paragraph 8.6.
7. Press the OK key for 3 seconds.
At this point the stove activates the switching on phase.
The following writing appears on the display:
Manuale d’uso e manutenzione modelli HYDRO
Pag.16
15/06/11
7.2. Display in modalità “BASE”
N.B.: Il simbolo del RISCALDAMENTO/SANITARIO indica la posizione della valvola a tre vie (solo su modelli che prevedono il kit sanita-
rio incorporato nella termostufa mod. HRV160 - HR200)
N.B.2: Il simbolo del pulitore è attivo solo su modelli di stufe aventi il sistema di pulitore automatico.
Pulsante “1”
: pulsante accesso al “Set temp. ambiente - Set temp. acqua caldaia“ e regolazione con i tasti 1 e 2.
Pulsante “2”
: pulsante accesso al “Set potenza“ e regolazione con i tasti 1 e 2 (uniche potenze impostabili sono la potenza Min e Max)
Pulsante “OK”
: - pressione breve del pulsante per confermare i set temperatura impostati;
- dalla schermata di figura 15-A/B, pressione breve del pulsante per accedere al menu utente;
- sempre dalla schermata di figura 15-A/B, pressione con durata di 3 secondi del pulsante per accendere e spegnere la
stufa.
Le funzionalità di questo display quando utilizzato in modalità “BASE“ sono:
- accensione e spegnimento della stufa;
- settaggio temperatura ambiente e selezione del tipo di sonda (sonda in dotazione collegata in scheda o sonda integrata a display);
- settaggio tempertura acqua caldaia;
- settaggio potenza di lavoro (Min - Max).
7. Descrizione dei comandi e simbologia del display
L’innovazione di questo particolare display consiste nella comunicazione tramite onde convogliate a bassa tensione (12 volts) tra scheda
elettronica e display. La comunicazione avviene tramite un cavo bipolare (es: cavo delle casse di uno stereo) e la novità consiste nella
possibilità di installare il display a parete tramite una cornice optional standardizzata per scatole elettriche 503.
7.1. Display in visualizzazione “SAVE LIGHT”
Modalita` per una rapida visualizzazione della temperatura
ambiente e dell’acqua in caldaia.
Pulsante “1”
: pulsante di visualizzazione e modifica del “Set
acqua caldaia“
Pulsante “2”
: pulsante di visualizzazione e modifica del “Set
ambiente“
Pulsante “OK”
: Pulsante di accesso alla schermata di Stand-by o
di conferma del set aria\acqua impostato
N.B.: La schermata di SAVE LIGHT si visualizza automaticamente
quando la retroilluminazione a display si spegne.
Fig.14
7.2.1 Accensione e spegnimento della stufa
Prima di effettuare la prima accensione della stufa seguire la seguente procedura:
1. Inserire il cavo di alimentazione.
2. Posizionare l’interruttore posto sul retro della stufa in posizione 1.
3. Verificare che l’impianto sia collegato con la canna fumaria.
4. Caricare il serbatoio con pellet di 6 mm
6. Effettuare il caricamento della coclea come descritto nel paragrafo 8.6.
7. Premere il tasto OK per 3 secondi.
A questo punto la stufa effettuerà la fase di accensione.
Sul display appariranno le seguenti diciture:
Orario
Temperatura ambiente
Stato stufa
Temperatura acqua caldaia
Stato stufa
Estate
Riscaldamento
Pulitore attivo
Circolatore in funzione
Sistema RDS disattivato
Inverno
Sanitario
Fig.15-A
Fig.15-B
Display in “SAVE LIGHT” mode
Display in modalità “BASE“
• SWITCH ON (waiting time varies depending on the factory parameters)
• WAITING FLAME (waiting time varies depending on the factory parameters)
• FLAME PRESENT (waiting time varies depending on the factory parameters)
• WORK (waiting time varies depending on the factory parameters)
Room temperature setting
Setting the room temperature is distinguished for models (HR100-200) and with ventilation (HRV120-135-160):
- stoves HR100 - HR200 with room temperature setting that manages stove modulation;
- stoves HRV120 - HRV135 - HRV160 with room temperature setting that exclusively manages ventilation
regulation (see paragraph 7.3.8. “VENTILATION MENU”).
Working Modulation
Working Modulation
Boiler water temperature
Room temperature
Stove status
Active cleaner
Summer
Circulator on
Heating
RDS system deactivated
Time
Stove status
Winter
Sanitary
Manuale d’uso e manutenzione modelli HYDRO
Pag.16
15/06/11
7.2. Display in modalità “BASE”
N.B.: Il simbolo del RISCALDAMENTO/SANITARIO indica la posizione della valvola a tre vie (solo su modelli che prevedono il kit sanita-
rio incorporato nella termostufa mod. HRV160 - HR200)
N.B.2: Il simbolo del pulitore è attivo solo su modelli di stufe aventi il sistema di pulitore automatico.
Pulsante “1”
: pulsante accesso al “Set temp. ambiente - Set temp. acqua caldaia“ e regolazione con i tasti 1 e 2.
Pulsante “2”
: pulsante accesso al “Set potenza“ e regolazione con i tasti 1 e 2 (uniche potenze impostabili sono la potenza Min e Max)
Pulsante “OK”
: - pressione breve del pulsante per confermare i set temperatura impostati;
- dalla schermata di figura 15-A/B, pressione breve del pulsante per accedere al menu utente;
- sempre dalla schermata di figura 15-A/B, pressione con durata di 3 secondi del pulsante per accendere e spegnere la
stufa.
Le funzionalità di questo display quando utilizzato in modalità “BASE“ sono:
- accensione e spegnimento della stufa;
- settaggio temperatura ambiente e selezione del tipo di sonda (sonda in dotazione collegata in scheda o sonda integrata a display);
- settaggio tempertura acqua caldaia;
- settaggio potenza di lavoro (Min - Max).
7. Descrizione dei comandi e simbologia del display
L’innovazione di questo particolare display consiste nella comunicazione tramite onde convogliate a bassa tensione (12 volts) tra scheda
elettronica e display. La comunicazione avviene tramite un cavo bipolare (es: cavo delle casse di uno stereo) e la novità consiste nella
possibilità di installare il display a parete tramite una cornice optional standardizzata per scatole elettriche 503.
7.1. Display in visualizzazione “SAVE LIGHT”
Modalita` per una rapida visualizzazione della temperatura
ambiente e dell’acqua in caldaia.
Pulsante “1”
: pulsante di visualizzazione e modifica del “Set
acqua caldaia“
Pulsante “2”
: pulsante di visualizzazione e modifica del “Set
ambiente“
Pulsante “OK”
: Pulsante di accesso alla schermata di Stand-by o
di conferma del set aria\acqua impostato
N.B.: La schermata di SAVE LIGHT si visualizza automaticamente
quando la retroilluminazione a display si spegne.
Fig.14
7.2.1 Accensione e spegnimento della stufa
Prima di effettuare la prima accensione della stufa seguire la seguente procedura:
1. Inserire il cavo di alimentazione.
2. Posizionare l’interruttore posto sul retro della stufa in posizione 1.
3. Verificare che l’impianto sia collegato con la canna fumaria.
4. Caricare il serbatoio con pellet di 6 mm
6. Effettuare il caricamento della coclea come descritto nel paragrafo 8.6.
7. Premere il tasto OK per 3 secondi.
A questo punto la stufa effettuerà la fase di accensione.
Sul display appariranno le seguenti diciture:
Orario
Temperatura ambiente
Stato stufa
Temperatura acqua caldaia
Stato stufa
Estate
Riscaldamento
Pulitore attivo
Circolatore in funzione
Sistema RDS disattivato
Inverno
Sanitario
Fig.15-A
Fig.15-B
Rapid display mode of room and hot water temperatures.
Button “1” :
button to display and change “Set boiler water“
Button “2” :
button to display and change “Set room“
“OK” button:
Button to access the Stand-by screen or
to confirm air/water set
N.B.: The SAVE LIGHT screen automatically displays when the
display backlighting switches off.
Summary of Contents for HRV 180 PLUS
Page 2: ...HRV 180 PLUS MANUALE D USO E MANUTENZIONE...
Page 3: ......
Page 17: ...Manuale uso e manutenzione HRV 180 PLUS Pag 16 Rev 2 04 12 2020 ITA 1 2 3 4 5 6...
Page 47: ...DATE WORK PERFORMED MAINTENANCE...
Page 48: ...DATE WORK PERFORMED MAINTENANCE...
Page 50: ...HRV 180 PLUS MANUEL D UTILISATION ET D ENTRETIEN...
Page 51: ......
Page 55: ......
Page 65: ...Manuel d utilisation et d entretien HRV 180 PLUS Page 16 Rev 2 04 12 2020 FR 1 2 3 4 5 6...
Page 92: ......
Page 95: ...DATE WORK PERFORMED MAINTENANCE...
Page 96: ...DATE WORK PERFORMED MAINTENANCE...
Page 98: ...HRV 180 PLUS USE AND MAINTENANCE MANUAL...
Page 99: ......
Page 103: ......
Page 112: ...Use and maintenance manual HRV 180 PLUS Page 15 Rev 2 04 12 2020 EN 1 2 3 4 5 6...
Page 141: ...DATE WORK PERFORMED MAINTENANCE...
Page 142: ...DATE WORK PERFORMED MAINTENANCE...
Page 143: ......
Page 144: ......
Page 146: ...HRV 180 PLUS BEDIENUNGS UND WARTUNGSHANDBUCH...
Page 147: ......
Page 151: ......
Page 160: ...Bedienungs und Wartungshandbuch HRV 180 PLUS S 15 Rev 2 04 12 2020 DE 1 2 3 4 5 6...
Page 188: ......
Page 191: ...DATE WORK PERFORMED MAINTENANCE...
Page 192: ...DATE WORK PERFORMED MAINTENANCE...
Page 194: ...HRV 180 PLUS MANUAL DE USO Y MANTENIMIENTO...
Page 195: ......
Page 199: ......
Page 208: ...Manual de uso y mantenimiento HRV 180 PLUS P g 15 Rev 2 04 12 2020 ES 1 2 3 4 5 6...
Page 237: ...DATE WORK PERFORMED MAINTENANCE...
Page 238: ...DATE WORK PERFORMED MAINTENANCE...
Page 239: ......
Page 240: ......