Weights fitting at “6 o'clock” (without the use of
laser emitter).
TO USE THIS MODE, IT IS NECES-
SARY THAT THE RELEVANT FUNC-
TION IS ENABLED
ON THE
MENU "OPTIONS" DESCRIBED IN
PAR. 15.1.
TO USE THIS WEIGHT APPLICA-
TION MODE THE OPERATOR
MUST REMEMBER THE PRECISE
POINT WHERE THE MEASURE-
MENT WAS TAKEN WITH THE
DISTANCE-DIAMETER CALIPER
ARM.
USING THIS MODE, THE MA-
CHINE ALLOWS YOU TO APPLY
ANY ADHESIVE WEIGHTS THAT
WOULD BE APPLIED WITH DIS-
TANCE/DIAMETER CALIPER AT
"6 O'CLOCK". IF, AFTER YOU EN-
ABLE THIS MODE, ON BALANCING
PROGRAM APPEARED AGAIN THE
ICON (ONLY IN THIS CASE)
THE ADHESIVE WEIGHT WILL BE
APPLIED TO "12 HOURS".
At the end of the spin, the wheel stops in place to
apply the weight at "6 o'clock". The positioning of
the weight (s) in depth shall be at the discretion of
the operator, depending on where remembers taking
the measure.
BE SURE TO APPLY THE (INTER-
NAL OR EXTERNAL) WEIGHT AS
INDICATED BY THE 2 GREEN
ARROWS
(
Fig. 56 ref. 2 or 3
)
ON
THE CORRESPONDING MONITOR
SCREEN.
•
Weights fitting at “12 o'clock” (with the use of
laser emitter) (optional).
TO USE THIS MODE, IT IS NECES-
SARY THAT THE RELEVANT FUNC-
TION IS ENABLED
ON THE
MENU "OPTIONS" DESCRIBED IN
PAR. 15.1.
This function indicates, through the 2 laser pointers
placed on the machine (frame and wheel cover), the
centre line position (at “12 o'clock”) of the counter-
weight in the programs that require the clip weights
(ex: dynamic) for the wheel balancing.
Therefore, at the end of the measuring cycle, when
the wheel stops in position to fit the clip weight (green
arrows an the screen), the laser corresponding to the
side to balance (external side see
Fig. 57
and internal
side see
Fig. 58
) turns on, projecting a line onto the
rim edge.
Fig. 57
Fig. 58
G3.150 - GP3.150 - G3.150S - GP3.150S - G3.150WS - GP3.150WS - G3.150WSPLUS - GP3.150WSPLUS - G3.150SA - G3.150WSA
RAVAGLIOLI S.p.A.