Maintenance and service
115
12
12.5.1 Check
In order to check the metering slide adjustment, the mechanism must be
freely movable.
1.
Park the machine safely on the ground or on a pallet. Ensure the ground is
even and secure!
2.
Remove both spreading discs.
3. Versions K/R/D
Connect the hydraulic hoses for the hydraulic metering slide actuator to the
hydraulic unit or tractor.
Versions C/Q
Connect the E-CLICK terminal or QUANTRON to the tractor.
4.
Start the tractor/unit/transformer.
5.
Close the metering slide.
6.
Switch off the tractor and remove the ignition key, or switch off the unit/trans-
former.
7. Versions K/R/D/C
: Adjust the stopper on the spreading volume scale to po-
sition 130 (for seeds or slug pellets to position 9).
Start the tractor / unit / transformer.
Open the metering slide until you reach the previously set stopper.
Version Q
: Open metering slide (position 130).
Move to the test points (see the operator's manual of the control unit).
8.
Switch off the tractor and remove the ignition key, or switch off the unit / trans-
former.
NOTICE
As the machine has a metering scale for each side, the adjustment work must
be carried out on both the
right
and
left
sides.
9.
Lower link pin
∅
= 28 mm
(for seeds or slug pellets, in-
sert the adjustment lever
∅
= 8 mm
) into the right or
left metering opening.
Figure 12.5:
Lower link pin in metering
opening
Summary of Contents for MDS 8.2
Page 8: ...Intended use 1 2...
Page 28: ...Safety 3 22...
Page 38: ...Technical data 4 32...
Page 42: ...Axle load calculation 5 36...
Page 44: ...Transportation without tractor 6 38...
Page 86: ...Machine settings 8 80...
Page 96: ...Calibration and discharging residual material 9 90...
Page 110: ...Important information on spreading 10 104...
Page 114: ...Faults and possible causes 11 108...
Page 146: ......