5.7 Function FLOWM TEST
5.8 Function EXT.BOARD TEST
Function: Check the Flowmeter
Start/Stop:
↓
Display:
Continuous display of FM signal.
100 FM-Imp. = ca. 1/2 dl.
0 0 99
Flowmeter P1 (coffee)
5.8.1 24V
OUTPUTS.
Function:
Check the 8 (24VDC) outputs on
the extension card
Selection: +/-
Start/Stop:
↓
Status:
1 = Component activated
0 = Component not activated
MP1
0
Component
Status
Display
Component
Jack on ex-
tension card
LED
(red)
MP 1
0
Milk pump M4 (left milk outlet / foam)
J46 / 1-2
3
MP 2
0
Milk pump M5 (right milk outlet / milk)
J46 / 3-4
4
CWV
0
Cold water valve for automatic milk rinse
J45 / 12-11
10
SV
0
Steam valve for automatic milk rinse
J45 / 10-9
9
ABV
0
Air bleed valve for automatic milk rinse
J45 / 8-7
8
AFV
0
Air foaming head valve
J45 / 5-6
7
RES(2,3)
0
Spares
J45 / 4-1
6, 5
5.8.2 SIGNAL
INPUTS..
24V OUTPUTS..( press + button)
Function:
Check the 8 (24VDC) inputs on
the extension card (Print ok)
Status:
1 = signal active
0 = signal not active
Statusanzeige
0 0 0 0 1 1 0 0
Milchsensor
Bohnensensor
Page 34
Summary of Contents for EGRO 5511
Page 1: ...EGRO 5511 Technical Manual Technical Manual ...
Page 2: ......
Page 4: ...Page 4 ...
Page 5: ...EGRO 5511 Manual SECTION 1 INTRODUCTION OVERVIEW Page 5 ...
Page 8: ...Page 8 ...
Page 9: ...EGRO 5511 Manual SECTION 2 INSTALLATION Page 9 ...
Page 15: ...Page 15 ...
Page 16: ...EGRO 5511 Manual SECTION 3 PROGRAMMING Page 16 ...
Page 40: ...Page 39 ...
Page 41: ...EGRO 5511 Manual SECTION 4 ELECTRICAL Page 40 ...
Page 50: ...Page 49 ...
Page 51: ...Page 50 ...
Page 52: ...Page 51 ...
Page 53: ...EGRO 5511 Manual SECTION 5 HYDRAULIC STEAM Page 52 ...
Page 58: ...EGRO 5511 Manual HYDRAULIC STEAM Brew Group Assembly D D F G C C C C E E H B A Page 57 ...
Page 60: ...Page 59 ...
Page 61: ...EGRO 5511 Manual SECTION 6 ADJUSTMENT MAINTENANCE Page 60 ...
Page 69: ...5 Page 68 ...