EGRO 5511
Manual
5.2 Function HEATER TEST
Function:
Switch on heaters manually
Selection: +/-
Start/Stop:
↓
Status:
0 = Heater off
1 = Heater on
Display:
Current temperature in °C
C E1
0
000C
Component
Status
Temperature in °C
Danger!
The heater must be switched off manually. There is no automatic
off switch!
Danger of overheating!
Display
Component
Jack on control card
LED
(red)
C
E1
0
000C
Coffee boiler heater
J5/1-2 (+24V=) SSR
7
S E2
0
OK
S E2
0
N OK
Steam boiler heater (OK =
Temp. reached, pressure
switch open)
Pressure is too low
J5/3-4 (+24V=) SSR
8
The measuring range of the temperature display is 0°C to 118°C.
Higher temperatures are displayed as 199°C.
5.2.1
Electrical Resistance of the NTC Temperature Sensors
Temperature °C
Resistance k
Ω
Temperature °C
Resistance k
Ω
0°C
32.6 k
Ω
80°C
1.2 k
Ω
25°C
10 k
Ω
100°C
0.7 k
Ω
50°C
3.6 k
Ω
120°C
0.39 k
Ω
Page 31
Summary of Contents for EGRO 5511
Page 1: ...EGRO 5511 Technical Manual Technical Manual ...
Page 2: ......
Page 4: ...Page 4 ...
Page 5: ...EGRO 5511 Manual SECTION 1 INTRODUCTION OVERVIEW Page 5 ...
Page 8: ...Page 8 ...
Page 9: ...EGRO 5511 Manual SECTION 2 INSTALLATION Page 9 ...
Page 15: ...Page 15 ...
Page 16: ...EGRO 5511 Manual SECTION 3 PROGRAMMING Page 16 ...
Page 40: ...Page 39 ...
Page 41: ...EGRO 5511 Manual SECTION 4 ELECTRICAL Page 40 ...
Page 50: ...Page 49 ...
Page 51: ...Page 50 ...
Page 52: ...Page 51 ...
Page 53: ...EGRO 5511 Manual SECTION 5 HYDRAULIC STEAM Page 52 ...
Page 58: ...EGRO 5511 Manual HYDRAULIC STEAM Brew Group Assembly D D F G C C C C E E H B A Page 57 ...
Page 60: ...Page 59 ...
Page 61: ...EGRO 5511 Manual SECTION 6 ADJUSTMENT MAINTENANCE Page 60 ...
Page 69: ...5 Page 68 ...