Raisecom
RC3000-15 (P100R001) Hardware Description
9 Asynchronous data cards
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
128
9.3.2 Version
Card
Version
RC3000-15-8RS485
A
9.3.3 Slots
Chassis version
Slot
E.30 and E.20
1–6 and 9–13
9.3.4 Interfaces
Interface type
Table 9-14 lists interfaces on the 8RS485 card.
Table 9-14
Interfaces on the 8RS485 card
Name
Type
Description
1–8
RS485 or
RS422
You can configure each interface to RS485 or RS422 in the
following ways:
CLI: configure the type for each interface individually.
Network management software: configure the type for each
interface individually.
DIP switch: SW2 is used to configure the interface type. If
you configure SW2 to OFF, all the 8 interfaces will be
configured to RS485 (half duplex); if you configure SW2 to
ON, all the 8 interfaces will be configured to RS422 (full
duplex).
If no configurations for the 8RS485 card are saved on
the cross connection card inserted to the RC3000-15,
configuring the DIP switch takes effect.
If configurations for the 8RS485 card are saved on
the cross connection card inserted to the RC3000-15,
these configurations take effect.
Interface parameter
Table 9-15 lists parameters of the 8RS485 interface.