5.2.2 Ethernet cable
Introduction
The Ethernet cable used on the iTN8600-I has the following functions:
Connect the iTN8600-I with the out-of-band network management network through the
SNMP interface.
Connect one iTN8600-I with the out-of-band network management interface on another
iTN8600-I through the EXT interface to form cascaded network management. The other
iTN8600-I do not need to be connected to the out-of-band network management network.
Appearance
Figure 5-4 shows the Ethernet cable.
Figure 5-4
Ethernet cable
Wiring
Table 5-15 lists the wiring of EIA/TIA 568A and EIA/TIA 568B standards.
Table 5-15
Wiring of EIA/TIA 568 A and EIA/TIA 568 B standards
Connector (RJ45)
EIA/TIA 568A
EIA/TIA 568B
PIN 1
White/Green
White/Orange
PIN 2
Green
Orange
PIN 3
White/Orange
White/Green
PIN 4
Blue
Blue
PIN 5
White/Blue
White/Blue
PIN 6
Orange
Green
PIN 7
White/Brown
White/Brown
PIN 8
Brown
Brown
Both RJ45 connectors of the straight-through cable follow EIA/TIA568 B standard wiring, as
shown in Figure 5-5.