Rain Master Eagle User Manual
6.0 Setup Key Operations
- 67 -
6.13.3 Unscheduled Flow Limit
This feature allows you to program the Unscheduled Upper Flow Limit. This is the maximum
flow that the controller will allow whenever there are no stations on. With no irrigation, and a
Normally Closed Master Valve, the typical installation should have no flow and the limit should
be set to zero. For systems which have a Normally Open Master Valve and the possibility of
supplemental watering due to quick coupler manual devices, you have the option of setting a non-
zero value which will be allowed when the controller does not have any active stations. If this value
is exceeded an unscheduled flow fault occurs.
This SETUP function will be skipped if you have not enabled the flow features.
EXAMPLE
: Select an Unscheduled Flow Limit of 25 GPM.
Continue to press:
SETUP
Until display indicates:
unsch200
Press:
ENTER
Display will indicate:
unsch025
Press:
QUIT
The controller will return to the Automatic Mode.
6.13.4 Flow Check Delay
The Flow Check delay feature allows you to program a delay after any change of stations for which
no flow limits will be checked.
Whenever there is a change in stations (a station gets turned on or off) the controller will not
check for flow limit faults from the time of the change until this delay has expired; this gives the
system time to stabilize before any flow limit checking takes place.
The flow check delay can be set, from 1 to 6 minutes, in 1 minute increments.
This SETUP function will be skipped if you have not enabled the flow features.
EXAMPLE
: Set a flow check delay to 4 minutes,
Continue to press:
SETUP
Until display indicates:
fdelay 2
Press:
ENTER
Display will indicate:
fdelay 4
Press:
QUIT
The controller will return to the Automatic Mode.