Rain Master Eagle User Manual
C Appendix – Programming Examples
- 109 -
EXAMPLE
: Set Stations 19 – 26 for a runtime of twenty (20) minutes
Press:
QUICK
STATIONS
Controller will display:
2 PT- 100
2 LO-
Press:
ENTER
Controller will display:
2 H I-
Press:
ENTER
Controller will display:
2 LN-
Press:
ENTER
The Controller returns to the Automatic Mode.
The final setting is the start time of the program. Program Two (2) is to water in the evening. The
evening watering must not start before 7:30 PM. Use the REVIEW key to check the total water
length (WATER WINDOW) of Program Two (2).
EXAMPLE
: Check watering length of Program Two (2)
Press:
PROGRAM
ENTER
REVIEW
REVIEW
Controller will display:
total
02h 40m
The controller has calculated the total watering time of Program Two (2), to be 2 hours and 40
minutes. The evening Start Time will be 7:30 PM.
Press:
QUIT
The controller will return to the Automatic Mode.
Summary of Contents for RME EAGLE EG Series