PROGRAMMING OF TOXIRAE
4 - 23
4.6.2 Set Datalogging Period
The datalogging period can be programmed from one to
3,600 seconds (1 hour) with one-second increment.
1. "Set datalogging period" is the second sub-menu item
in Table 4.4. Display shows "Period?" message.
2. Press the
[Y/+]
key
to
set
the
period.
- Display shows "+- 0060" with the left-most digit
flashing, where “0060” is the previously stored data
logging period in unit of seconds.
3. To modify this period, starting from the left-most digit,
use the
[Y/+]
or
[N/-]
key to change the digit value and
press the
[MODE]
key momentarily to advance to the
next digit. The flashing digit will move to the next
digit to the right. Repeat this process until all 4 digits
of the new period are entered. Press and hold the
[MODE]
key for 1 second to exit data entry mode. If
there is any change to the existing value, the display
shows "Save?" Press the
[Y/+]
key to accept the new
value and exit the datalog sub-menu. Press the
[N/-]
key to discard the changes and move to the next menu
option.
4.
To preserve the previously stored period, press
and hold
the
[MODE]
key for 1 second. The unit will exit data
entry mode and move to the next menu item in Table
4.1.