PROGRAMMING THE AREARAE
4-43
4.8.3 Enable/Disable Sensor
This function allows you to selectively enable or disable
individual sensors in the AreaRAE. When a sensor is disabled,
the sensor does not measure or display the gas concentration.
1. “Enable / Disable Sensors?” is the second submenu. Press
[Y/+]. The display shows all the installed sensors in the
monitor. A previously enabled sensor is marked by an “*”
next to the sensor name. The cursor blinks at the first
sensor location. Press [Y/+] to enable the sensor and [N/-]
to disable the sensor.
TOX1
VOC
TOX2
CO*
VOC*
H2S*
LEL* pick
OXY*
LEL
OXY
TOX1
VOC
Gamma
CO*
VOC*
Gmm*
LEL*
pick
OXY*
LEL
OXY
AreaRAE
AreaRAE Gamma
2. Press [MODE] momentarily to move from one sensor
location to the next one. Repeat Step 2 until all the sensors
that need to be enabled are selected. Press and hold
[MODE] for 1 second to save the new sensor selection.
3. The display shows “Save?” To confirm the new selection,
press [Y/+] to accept the change. Press [N/-] or [MODE] to
discard the change and move to the next submenu.