PPC7A Product Manual
Configuration
4-2
1
st
Edition
Default Link Settings
The following table shows the factory default link settings:
L
INK
S
ETTING
A
CTION
E1
Out
Standby supply voltage is 5 volts
E3
Out
User FLASH Write Protected
E4
Out
Boot from System FLASH
E5
Out
FLASH Write Protected
E6
Out
ECC Disabled
E7
Out
Select main Boot Image
E8
Out
Boot from System FLASH
E9
Out
System FLASH Write Protected
E13
Out
On-board SCSI terminators
disabled
E14
Out
Reset Switch enable
E2, E10, E11,E12
Out
ID links (board ID = 15)
If you wish to change any of these linkable options, refer to the appropriate section(s) in the following
pages.
$
Note:
If you are about to install your board and power-up for the first time, leaving your board in the default
configuration (as above), will enable board operation to be proved prior to tackling any more
configuration issues.
RTC Standby Supply Voltage Link (E1)
This link selects the voltage of the standby supply to the I²
C
RTC (DS1337). As the normal VME
standby voltage is 5 Volts, the link should not normally be fitted. However, the PPC7A can be linked to
use a backup supply of 3.3 Volts.
$
Note:
If the link is fitted the Backup supply should never be allowed to go above 3.5 Volts otherwise damage to
the DS1337 device might result.