Crash of the product due to insufficient load handling device!
Severe injuries up to death.
Only use tested and appropriate load handling devices.
Load handling device only to be carefully connected on the main chassis
or on the intended spots.
Transport:
2.2.2.4 Storage
If the RACO electrical cylinder is not to be installed immediately, it must be stored horizontally, in a dry
area, and protected from impacts and the effects of weather. Bare metal areas must be protected with
grease or oil, and the push/pull tube must be retracted.
If being stored for more than 2 years, it is recommended that the lubricants are replaced completely.
The RACO electrical cylinder should only be installed immediately prior to commissioning.
Before commissioning, you must first carry out a running check, measuring the idling current or the
nominal current under load. Note these values, and notify us of them if necessary.
The storage temperature should be within the range –10 °C to +40 °C.
Revision: 03
2.2-8/17