12.1 Checking the hydraulic system
a
CAUTION:
NEVER place a hand over escaping hydraulic fluid.
Leaks must be located with a tool. Risk of injury
or infection due to hydraulic fluid. Hydraulic fluids
escaping under high pressure are able to penetrate
the skin and cause serious, even fatal injuries.
a
CAUTION:
Your implement may be equipped with hydraulic
accumulators. These are pressurised and it
is dangerous and prohibited to remove the
accumulators or their piping. This operation may
only be performed by qualified personnel (consult
your dealer).
a
CAUTION:
Before working on the hydraulic circuit, set the
implement down on the ground and depressurise
the hydraulic circuit.
a
CAUTION:
Never heat, weld, saw, grind or flame cut close
to hydraulic circuits or components or any
other flammable parts. For welding work on the
implement, disconnect the tractor battery and
protect the hydraulic circuits so that they are not
damaged by welding sparks and spatter.
∙
Check hydraulic hoses for wear (deterioration of the external
sheath, wear etc.).
∙
Check that couplings, components, etc. are securely
tightened.
∙
Drain the implement if you need to replace components in the
hydraulic circuit.
a
CAUTION:
Never open, pierce, weld or perform work on the
hydraulic accumulators.
i
IMPORTANT:
Replace hydraulic hoses with others having the
same technical specifications.
i
IMPORTANT:
Collect hydraulic oil, hydraulic accumulators, tyres
and take them to a dealer or an approved collection
point. Do not abandon them in the environment.
12.2 Checking the pneumatic system
a
CAUTION:
Your implement may be equipped with air tanks.
These are pressurised and it is dangerous and
prohibited to remove the tanks or their piping.
This operation may only be performed by qualified
personnel (consult your dealer).
a
CAUTION:
Before working on the pneumatic circuit, set the
implement down on the ground and depressurise
the circuit.
a
CAUTION:
Never heat, weld, saw, grind or flame cut close
to pneumatic circuits or components or any
other flammable parts. For welding work on the
implement, disconnect the tractor battery and
protect the pneumatic circuits so that they are not
damaged by welding sparks and spatter.
∙
Check pneumatic hoses for wear (deterioration of the external
sheath, wear etc.).
∙
Check that couplings, components, etc. are securely
tightened.
a
CAUTION:
Never open, pierce, weld or perform work on the air
tanks.
i
IMPORTANT:
Replace pneumatic hoses with others having the
same technical specifications.