Instruction book
2012 2039 28
101
Reference
Description
OL1
Overload Relay (Drive Motor)
OL4
Overload Disconnect (Fan Motor)
CPT1
Control Power Transformer
5. Fit the air outlet (AV); see section Introduction for the position of the valve. Close the valve
Connect the air net to the valve.
6. Check the fluid level.
3 to 5 minutes after stopping, the fluid level should be between the top of the sight glass (GI) and the filling
point (FC).
Position of oil level sight-glass
7.
If applicable: provide labels, warning the operator that
:
The compressor may automatically restart after voltage failure.
8. Check the voltage between the three phases before using the unit for the first time