Maintenance
6.1 Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
Stop the compressor.
Press the emergency stop button.
Switch off the voltage.
Close the air outlet valve and open, if provided, the manual condensate drain
valve.
Depressurise the compressor.
For detailed instructions, see section
Problem solving
. The operator must apply all
relevant
Safety precautions
Before lifting the electric motor, all build-on parts shall be removed.
Service kits
For overhauling or carrying out preventive maintenance, service kits are available (see section
Service contracts
QUINCY offers several types of service contracts, relieving you of all preventive maintenance work. Consult
your Customer Centre.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
The local Customer Center may overrule the maintenance schedule, especially the service intervals,
depending on the environmental and working conditions of the compressor.
The longer interval actions and checks must also include the shorter interval actions and checks.