4. Unscrew fluid filler plug (FC) one turn to permit any pressure left in the system to escape. Wait a few
minutes.
5. Remove the plug and add fluid until the level reaches the filler opening.
6. Fit and tighten the plug (FC).
7. Unlock the emergency stop button and press the "Reset key" on the controller before restarting.
5.5 Stopping
Regulator
Q control panel
Procedure
Step
Action
-
Press stop button (13). Automatic operation LED (7) goes out and the compressor stops after
30 seconds of unloaded operation.
-
To stop the compressor in the event of an emergency,
press emergency stop button. Alarm
LED flashes (3).
Remedy the problem cause and unlock the button by pulling it out.
Navigate to the Stop icon on the display by means of the navigation keys (12) and press
the Select key.
Press reset.
Do not use emergency stop button for normal stopping!
-
Close the air outlet valve (AV).
-
Press the test button on the top of the electronic water drain(s) until the air system between the
air system receiver and the outlet valve is fully depressurised. Switch off the voltage.
-
If available, open the condensate drain valve of the compressor to drain the water trap
completely.