Instruction book
2012 2039 28
108
■OPERATIONS THAT MAY BE CARRIED OUT BY THE USER
■■ OPERATIONS THAT REQUIRE SKILLED PERSONNEL
Interval operations
First 500 hours
■■ Oil Fluid Sample
■■ SPM measurement
■ Tighten the screws fixing the electric cables
Every 2000 hours
■■ Oil Fluid Sample
■■ SPM Measurements
■ Re-tighten all power cable connections
Every 4000 hours
■■ Replace the Oil filter
■■ Replace the Air filter
■■ Re-grease motor bearings
Every 8000 hours
■■ Oil Separator kit & Scavenge Line Kit
■■ Unloader Kit
■■ Oil Stop and Check Valves Kits
■■ Minimum Pressure Valve Kit
■■ Thermostatic Valve Kit
■■ Change the Fluid
(*See note below)
* The compressor must be maintained with QuinSyn
‐
Plus (8,000 hour maximum), QuinSyn
‐
XP (12,000
hour maximum) or QuinSyn
‐
F food grade (6,000 hour maximum). Maximum fluid change intervals are
noted per fluid. Actual fluid change interval is to be determined by fluid sampling report, not to exceed
maximum fluid change interval. Fluid samples must be taken every 2,000 hours or as directed by the
analysis report. For light usage units, a fluid sample must be taken a minimum, of every six (6) months,
beginning at start
‐
up.
Always consult your supplier if a service timer setting has to be changed.
For the change interval of fluid and oil filter in extreme conditions, consult your
Customer Centre.
Any leakage should be attended to immediately. Damaged hoses or flexible joints
must be replaced.
6.2
Storage after installation
Service kits
Run the compressor regularly, e.g. twice a week, until warm. Load and unload the compressor a few times.
If the compressor is going to be stored without running from time to time, protective
measures must be taken. Consult your supplier.