121
No.
Condition
Fault
Remedy
6
Safety valve blows after
loading
Inlet valve malfunctioning
Have valve checked
Minimum pressure valve
malfunctioning
Have valve checked
Safety valve out of order
Have valve replaced
Airend (AE) out of order
Consult your supplier
Oil separator element clogged
Have element replaced
7
Airend outlet temperature
or delivery air
temperature above
normal
Oil level too low
Check and correct
On air-cooled compressors,
insufficient cooling air or cooling
air temperature too high
Check for cooling air restriction
or improve ventilation of the
compressor room.
Avoid circulation of cooling air. If
installed, check capacity of
compressor room fan
Oil cooler clogged
Have valve tested
Thermostatic valve
malfunctioning
Clean cooler
Air cooler clogged
Consult your supplier
Airend (AE) out of order
Replace
Oil filter clogged
Have valve tested
8
Excessive Water Content
in fluid
Water drain intervals
Drain water as needed. to
reduce water content in fluid
below 200 PPM
Discharge temperature Too low
Check operation of thermostatic
valve or water regulating valve. If
condition continues, consult
QUINCY service department.