a) Activation of Programming Level A
Conditions
Mains power switch ON
Drive system not running
Operating mode: manual sewing must be ON (key T9 (P/M) dark)
Press key T10 (T/E)
Response:
Key T10 (T/E) becomes bright, the display shows in its righthand half the first parameter (parameter no.
and parameter value) associated with programming level A.
Sewing is not possible
- Programming
The
parameter number
is set by using keys P+ or P- (hundreds of parameter no.) and keys S+ or
S- (tens and units of parameter no.). The
parameter value
is programmed by using key L+ or L-
b) Deactivation of the Programming Level A
Press key T10 (T/E)
Response:
Key T10 (T/E) goes dark, the display returns to initial condition.
Sewing is possible.
9.1.2.2 Programming Level B (Technician Level)
This level is used for programming the control parameters which have to be modified or adapted very
rarely or only for starting operation of the system.
a) Preparation for Activation of the Programming Level B
Turn mains power switch OFF
Press and hold keys T9 (P/M) and T10 (T/E) simultaneously
Turn mains power switch ON
Release keys
Response:
The display shows a „
4
“ between program number and seam section.
Sewing is possible.
Q-41-MSII-2-EN
9.4
02-02-21
1 0 1 0 x x/00
1 0 1 0 1 1 1 6
1 0 1 0 x x/00
1 0 1 0 x x
4
00