Q-41-MSII-2-EN
9.8
02-02-21
9.2 User Programming via the Internal Mini Programming Panel (MPF)
Fig. 9.2
The
MPF
comprises the following functional elements:
- the six programming keys:
M
+++++
/
M
−−−−−
/
C
<<
<<
<<
<<
<<
/
C
>>
>>
>>
>>
>>
/
V
+++++
/
V
−−−−−
- the display: eight-digit LCD matrix
Each digit on the display is identified by a symbol for a sewing function.
The
MPF
is activated only when no external operating panel
OC-TOP
is connected to the control system.
When the drive system is turned on, message 01 is shown on the display for approx. 1 sec: type of control
system (e.g. Q41MSII).
Indication 01
:
Subsequently, Indication 02 is shown on the display: software status (e.g. 7Z_932_5).
Indication 02
:
After approx. 1 sec has elapsed, the display will show the indication 1
The following different options can be selected on the display:
Indication 1
: rated stitches for seam section S1 at seam beginning
Indication 2
: speed and rated stitches for seam section S2 at seam end
Indication 3
: sewing functions
Indication 4
: control parameters
Indication 5
: hardware test (<797> = I, see chapter 10.5)
Indication 6
: reset
M
C
V
+
>>
+
<<
_
_
3 3 3 3A
4 _
Q
1M_
S
5
7Z _
_
- 3 _
-
9 2
I I