Q-41-MSII-2-EN
10.3
02-02-21
To call up various functional elements within a test block such as advancing from an Input to the next,
use keys B+ and B- on the control panel
OC-TOP
or with the keys C>> / C<< on the
MCP
.
To activate functional elements selected, use key
D+
othe
OC-TOP
or the key
V+
on the
MCP
.
Test block 1
: Inputs
Indication:
The function assigned to the input displayed can be seen from chapter 12 „Connections Diagram for
Connectors“.
The designations E (for input) are located on the lefthand side of the connectors shown.
The keys or selectors assigned to the inputs are designated S in the connections diagram and have the
same numbers as the associated inputs, i.e.
key S1 is connected to input E1
key S2 is connected to input E2
key Sx is connected to input Ex.
The operating state of the input is signalled in the 7th digit of the display.
Key/switch open
→
Indication: 0
Key/switch closed
→
Indication: 1
In the righthand part of the display, the connecting plug and the pin number to which the displayed input
is connected are shown for the purpose of reference.
Test block 2
: Outputs
Indication:
The function assigned to the ouput displayed can be seen from chapter 12 „Connections Diagram for
Connectors“.
E0 1
0
X 1 : 5
Connecting plug
Pin no.
State of input
Input no.
Input
Connecting plug
Pin no.
State of output
Output no.
Output
A0 1
0
X 1 : 9