Q-41-MSII-2-EN
8.4
02-02-21
8.1.2 Functional sequence 1 (<799> = 1) without stop after seam end (<603> = II)
Functions:
chop at start
chop at end
chain vacuuming at start
chain vacuuming at end
thread tension release at start and at end
Switch condition of the keys at the
OC-TOP
:
Key
T9
(P/M) off (dark)
Key
T10
(T/E) off (dark)
Key
T6
on (bright)
Key
T7
on (bright)
Key
T11
on (bright)
Key
T12
on (bright)
Key
T15
on (bright)
Fig. 8.1b
max
0
0
1
0
- 2
+12
1
0
1
0
n
(AB)
S 1
<537>
<541>
<541>
<543>
(CD)
S 2
< 537>
1
0
ML
HACK
KESAU
FSL
<542>
<105>
<112>
<110>
<112>
<540>
<540>
(AB)
S 1
bright
dark
Pedal
*
A1
Outp.
*
A5
Outp.
*
see electrical connections diagram page 12.2
*
A6
Outp.
Motor runs
Thread tension release
Chain vacuum
Chopper
*
Outp. A8
Light-barrier
LS