DLT1/VS80 SCSI Interface Guide
81-81276-01 Rev A01
July 2004
4-103
03h MEDIUM ERROR
00
00
Medium Error
04
02
Unit Not Ready, LOAD Command Needed
0C
00
WRITE Error (possible medium problem, cleaning medium
needed)
11
00
Unrecovered Read Error
11
08
Unrecovered READ Error, Incomplete Block Read
14
00
Recorded Entity Not Found (logical DLT block not found)
15
02
Position Error Detected by Read of Medium
30
00
Incompatible Medium Installed
30
01
Unknown Format
3B
00
Sequential Positioning Error
3B
08
Repositioning Error
51
00
ERASE Failure
80
00
Calibration Error (use cleaning cartridge)
80
01
Cleaning Required (use cleaning cartridge)
81
00
Directory Read Error (use cleaning cartridge)
04h HARDWARE
ERROR
08
00
LUN Communication Failure
08
01
LUN Communication Timeout Failure
0C
80
Write SCSI FIFO CRC Error
11
80
Read SCSI FIFO CRC Error
11
81
Block Port Detected EDC Error
11
82
Block Port Detected Record CRC Error
15
01
Random Mechanical Positioning Error
21
01
Invalid Element Address
3B
08
Repositioning Error
3B
0D
Media Destination Element Full
a
Table 4-61.
Supported SK, ASC, and ASCQ (Hex) in Response to the REQUEST SENSE
Command
(Continued)
SK
ASC
ASCQ Description
Summary of Contents for DLTtape DLT1
Page 1: ...DLT1 VS80 SCSI Interface Guide...
Page 6: ...DLT1 VS80 SCSI Interface Guide vi July 2004 81 81276 01 Rev A01 Notes...
Page 12: ...Table of Contents xii July 2004 81 81276 01 Rev A01 Notes...
Page 16: ...List of Figures xiv July 2004 81 81276 01 Rev A01 Notes...
Page 20: ...List of Tables xviii July 2004 81 81276 01 Rev A01 Notes...
Page 24: ...Chapter 1 Introduction 1 4 July 2004 81 81276 01 Rev A01 Notes...
Page 32: ...Chapter 2 General SCSI Bus Operation 2 8 July 2004 81 81276 01 Rev A01 Notes...
Page 42: ...Chapter 3 SCSI Messages 3 10 July 2004 81 81276 01 Rev A01 Notes...
Page 181: ......