SCSI Commands
Quantum DLT 4000 Tape Drive
5-91
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
5.9.9 Changeable Parameters within MODE SELECT
The following table lists the MODE SELECT command’s changeable parameters
and their default, minimum, and maximum values. Descriptions of the various
parameters are provided in the discussions of the different mode pages within
MODE SELECT. Note that parameter rounding is supported for all parameters
except for the block descriptor length.
Table 5–44 Changeable Mode Parameters within MODE SELECT
Page: Parameter
Default
Minimum
Maximum
Header: Buffered Mode, Device Specific Byte
1
0
1
Block Descriptor Length
08h
00h
08h
Block Descriptor: Block Length
2.0 GB and 6.0 GB Mode
10.0 GB and 20.0 GB Mode
0
0
0
0
40000h
FFFFFFh
READ / WRITE Error Recovery (01h): PER bit
0
0
1
Control Mode (0Ah): RLEC
0
0
1
Data Compression (0Fh): DCE
1
0
1
Disconnect / Reconnect (02h): Maximum Burst Size
0080h
0000h
FFFFh
Disconnect / Reconnect (02h): DTDC
0
0
3
Device Configuration (10h): WRITE Delay Time
C8h
Fh
1964h
Device Configuration (10h): SEW
1
0
1
Device Configuration (10h): Select Data Compression
Algorithm
1
0
1
Summary of Contents for DLTtape DLT 4000
Page 1: ...DLT 4000 Tape Drive Product Manual November 10 2003 81 60043 04 ...
Page 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued ...
Page 6: ......
Page 24: ...About This Manual Quantum DLT 4000 Tape Drive xxiv ...
Page 62: ...Hardware Implementation 2 28 Quantum DLT 4000 Tape Drive ...
Page 100: ...Messages 4 12 Quantum DLT 4000 Tape Drive ...
Page 264: ...SCSI Commands 5 164 Quantum DLT 4000 Tape Drive ...
Page 274: ...Appendix B EEPROM Resident Bugcheck and Event Logs B 6 Quantum DLT 4000 Tape System ...
Page 280: ...Appendix C Updating the Firmware C 6 Quantum DLT 4000 Tape Drive ...
Page 298: ...Index Index 6 Quantum DLT4000 Tape Drive ...
Page 299: ......