Quantum DLT 4000 Tape Drive
C-1
Appendix C
UPDATING THE FIRMWARE
This appendix explains how to update the tape drive’s PCBA-resident firmware.
C.1
OVERVIEW
Using the tape drive’s front panel and a tape with the updated firmware image,
you can update the tape drive’s PCBA-resident firmware.
CAUTION
Version 2 of the DLT 4000 tape drive requires firmware code release
V130 or higher. The drive will not function properly if a lower
version of firmware code is installed.
If a powerfail occurs during the firmware update process (when the
new image is actually being programmed into the FLASH EEPROMs),
the tape drive’s PCBA will be rendered unusable. When performing
a firmware update, take all possible precautions to prevent power
failure to the tape drive.
C.2
CREATING A FIRMWARE UPDATE TAPE
To update the tape drive’s PCBA firmware, you need a tape cartridge with a copy
of the new firmware image. The firmware image must be byte-written without
compression onto the tape using the appropriate block size as defined in Table C-
1. The image must be “copied” onto the tape instead of using the backup utility.
Summary of Contents for DLTtape DLT 4000
Page 1: ...DLT 4000 Tape Drive Product Manual November 10 2003 81 60043 04 ...
Page 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued ...
Page 6: ......
Page 24: ...About This Manual Quantum DLT 4000 Tape Drive xxiv ...
Page 62: ...Hardware Implementation 2 28 Quantum DLT 4000 Tape Drive ...
Page 100: ...Messages 4 12 Quantum DLT 4000 Tape Drive ...
Page 264: ...SCSI Commands 5 164 Quantum DLT 4000 Tape Drive ...
Page 274: ...Appendix B EEPROM Resident Bugcheck and Event Logs B 6 Quantum DLT 4000 Tape System ...
Page 280: ...Appendix C Updating the Firmware C 6 Quantum DLT 4000 Tape Drive ...
Page 298: ...Index Index 6 Quantum DLT4000 Tape Drive ...
Page 299: ......