BMC
F
RONT
P
ANEL
U
SER
I
NTERFACE
4-2
Power Button
As previous described, the Power buttons provide one of the
sources for system status control.
ID Button
The control panel Chassis Identify button toggles the state of
the Chassis ID LED. If the ID LED is off, then a button press will
turn the LED on (blinking). If the LED is on, a button press or
IPMI Chassis Identify command will turn the LED off.
LEDs
The following table contains information on Status, ID and
Heartbeat LED's
The following table contains information on Status LED when
amber blinking.
Status LED Activity
N
O
.
S
TATUS
LED
A
CTIVITY
D
ESCRIPTION
1
Temperature
Sensor
Non-critical / critical event asserted
2
Fan Sensors
Non-critical / critical event asserted
3
Voltage Sen-
sors
Critical event asserted
4
Power Supply
State asserted
5
Processor
Thermal trip
6
Event Log-
ging Disable
SEL almost full
SEL full
7
Post Error
System firmware error
8
Memory
Correctable EEC error
Uncorrectable ECC error
Correctable ECC error logging limit reached
9
PCI-E Bus
Bus correctable error
Bus uncorrectable error
Bus fatal error
10
Watchdog 2
Timer expired
Hard Reset
Power Down
Power cycle
Status LED Activity (Continued)
N
O
.
S
TATUS
LED
A
CTIVITY
D
ESCRIPTION
Summary of Contents for STRATOS S200 Series S200-X12TS
Page 24: ...About the Server Chapter 1 ...
Page 50: ...Installing Hardware Chapter 2 ...
Page 95: ...BIOS Chapter 3 ...
Page 150: ...BMC Chapter 4 ...
Page 215: ...Connectors and Jumpers Chapter 5 ...
Page 218: ...Rail Kit Assembly Chapter 6 ...
Page 222: ...Troubleshooting Chapter 7 ...
Page 228: ...Installation and Assembly Safety Instructions Chapter 8 ...
Page 232: ...Safety Information Chapter 9 ...
Page 241: ...Regulatory and Compliance Infor mation Chapter 10 ...