I
NSTALLING
H
ARDWARE
R
EMOVING
M
EMORY
M
ODULES
2-18
Removing Memory Modules
21
Prerequisite:
Remove the top cover. See
Opening the Top Cover
on
page.
For CPU0 channel memory modules, remove the Mezza-
nine card assembly, Removing a 10GbE SFP+ Mezza-
nine Card Assembly on page 2-25.
CPU0 Memory Module Population Rules
N
UMBER
OF
DIMM
S
CPU0
C2
C1
B2
B1
A2
A1
1
V
2
V
V
3
V
V
V
4
V
V
V
V
5
V
V
V
V
V
6
V
V
V
V
V
V
CPU1 Memory Module Population Rules
N
UMBER
OF
DIMM
S
CPU1
D1
D2
E1
E2
F1
F2
1
V
2
V
V
3
V
V
V
4
V
V
V
V
5
V
V
V
V
V
6
V
V
V
V
V
V
CAUTION!
H
ANDLE
THE
MEMORY
MODULE
BY
THE
EDGES
AT
ALL
TIMES
.
WARNING!
Memory modules remain hot after the system is powered down.
Allow sufficient time for the memory modules to cool before
handling system components.
!
!
Summary of Contents for STRATOS S200 Series S200-X12TS
Page 24: ...About the Server Chapter 1 ...
Page 50: ...Installing Hardware Chapter 2 ...
Page 95: ...BIOS Chapter 3 ...
Page 150: ...BMC Chapter 4 ...
Page 215: ...Connectors and Jumpers Chapter 5 ...
Page 218: ...Rail Kit Assembly Chapter 6 ...
Page 222: ...Troubleshooting Chapter 7 ...
Page 228: ...Installation and Assembly Safety Instructions Chapter 8 ...
Page 232: ...Safety Information Chapter 9 ...
Page 241: ...Regulatory and Compliance Infor mation Chapter 10 ...