6-3
Installing the Outer Rail
1. Align the screws on the outer rail with the screw holes on
the front cabinet column.
2. Guide the screws on outer rail through the screw holes on
the front cabinet column until the rail clicks in place.
3. Extend the rear side of the outer rail, to reach the rear
cabinet column.
4. Guide the screws on outer rail through the screw holes on
the rear cabinet column until the rail clicks in place.
Installing the Outer Rail
5. Repeat the previous steps for the other side.
Installing the System Into the
Rack
Aligning the Rails
1. Align the inner rail with the outer rail.
2. Horizontally install the system half way into the slide rail.
3. Slide the release tab into
locked position
.
4. Slide the server into the rails till flush with the rack.
2
4
WARNING!
Prior installing the system into the slide rail, make sure the
ball bearing retainer is locked forward.
WARNING!
Heavy object. Two people are required to safely handle the
server. Always ask for assistance to install or remove the
server.
!
!
Summary of Contents for STRATOS S200 Series S200-X12TS
Page 24: ...About the Server Chapter 1 ...
Page 50: ...Installing Hardware Chapter 2 ...
Page 95: ...BIOS Chapter 3 ...
Page 150: ...BMC Chapter 4 ...
Page 215: ...Connectors and Jumpers Chapter 5 ...
Page 218: ...Rail Kit Assembly Chapter 6 ...
Page 222: ...Troubleshooting Chapter 7 ...
Page 228: ...Installation and Assembly Safety Instructions Chapter 8 ...
Page 232: ...Safety Information Chapter 9 ...
Page 241: ...Regulatory and Compliance Infor mation Chapter 10 ...