Q24
Tape
Library
Installation
and
Operations
Manual
© Copyright QUALSTAR 2014
68
Error
Code
Description
User
Action
Critical
Component
Status
89
Gripper
blocked
Run
‘Library
Verify
Test’,
after
several
occurrences
contact
technical
support
Media
changer
probably
defective.
Gripper
motor
not
connected
or
defect.
Gripper
motor
voltage
to
low.
Media
changer
controller
or
distribution
boards
defect.
Check
gripper
mechanism
according
stiffness
in
movement.
8A
Slider
blocked
Run
‘Library
Verify
Test’,
after
several
occurrences
contact
technical
support
Media
changer
probably
defective.
Slider
Motor
not
connected
or
defect.
Slider
motor
voltage
to
low.
Media
changer
controller
or
distribution
boards
defect.
Check
slider
mechanism
according
stiffness
in
movement.
8B
Elevator
blocked
Run
‘Library
Verify
Test’,
after
several
occurrences
contact
technical
support
Media
changer
probably
defective.
Elevator
motor
not
connected
or
defect.
Elevator
motor
voltage
to
low.
Media
changer
controller
or
distribution
boards
defect.
Check
elevator
mechanism
according
stiffness
in
movement
8C
Rotation
blocked
Run
‘Library
Verify
Test’,
after
several
occurrences
contact
technical
support
Media
changer
probably
defective.
Rotation
motor
not
connected
or
defect.
Rotation
motor
voltage
to
low.
Rotation
home
sensor
defect.
Rotation
sensor
connecting
cable
damaged.
Media
changer
controller
or
distribution
boards
defect.
8D
Sled
blocked
Run
‘Library
Verify
Test’,
after
several
occurrences
contact
technical
support
Media
changer
probably
defective.
Sled
motor
not
connected
or
defect.
Sled
motor
voltage
to
low.
Sled
home
sensor
defect.
Sled
sensor
connecting
cable
damaged.
Media
changer
controller
or
distribution
boards
defect.
Check
sled
mechanism
(guide
rail,
ducktail)
according
stiffness
in
movement.
8E
Cannot
find
gripper
block
within
the
expected
range
Run
‘Library
Verify
Test’,
after
several
occurrences
contact
technical
support
Media
changer
probably
defective.
Elevator
distribution
board
defect.
Cabling
incorrect.
Check
gripper
gears.