Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
46
A. Fuel Conversion
• Make sure the appliance is compatible with available
gas types.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specifi ed
and approved parts.
12
12
Gas Information
• Turn control knob on the valve to OFF position.
• Remove glass assembly (see Figure 15.A)
• (Remove logs, grate, and ember bed if already
installed.)
• Remove 2 screws holding pilot bracket to burner. See
Figure 11.1.
Kit contents:
Pilot injector #35
Burner orifi ce
Red pin
Conversion Label
Tools Required:
#2 phillips screwdriver
Straight screwdriver
5/32 allen wrench
3/8 & 11/16 wrenches
Figure 12.1 Remove Pilot Screws
• Remove 4 screws holding Burner in place and remove
burner. See Figure 12.2.
Figure 12.2 Remove Burner Screws
• Using a 3/8 wrench, unscrew and remove rear orifi ce
and discard. See Figure 12.3.
Figure 12.3 Remove Burner Orifi ce
• Unscrew and remove front orifi ce #46 and install in
rear.
• Install new orifi ce #56 in front.
• Open air shutters to fully open. See Figure 12.4.
• Replace burner and screws holding it in place.
Figure 12.4 Adjusting Air Shutter
Note:
Gas conversions should only be performed by a
qualifi ed service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas fi tter.
Converting to LP Gas