Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
14
Setting °F/°C Scale
The factory setting for temperature is degrees Fahrenheit
°F). To change this setting to degrees Centigrade (°C):
•
Remove the battery cover on the back of the transmitter
and locate the “setting button” at the top center of battery
compartment (see Figure 2.7).
• Push setting button and °F will begin fl ashing on the
LCD screen (see Figure 13.4, Location #8).
• Push the DOWN button on the transmitter to change °F
to °C.
•
Push “setting button” on transmitter and Centigrade (°C)
degree readings will display on LCD screen.
• Repeat this process to change back to Fahrenheit (°F)
reading, this time pushing the UP button.
NOTE:
LCD screen will return to normal state if setting
button is not pushed within 15 seconds.
Setting Desired Room Temperature - Ther-
mo Operations
This remote control system can be thermostatically
controlled when the transmitter is in the THERMO
mode. (THERMO must be displayed on the screen). The
transmitter will “sense” the room temperature every two
minutes automatically turning the fi replace ON or OFF
thermostatically.
To set the desired room temperature:
• Press the MODE button to place the transmitter into
THERMO mode. THERMO ON or OFF will display.
• Press the UP or DOWN button to select the desired
room temperature. The highest SET temperature is 99° F
(32° C). The lowest SET temperature is 45° F (6° C).
When the transmitter is in the THERMO mode, it should
be kept away from direct sources of heat such as fi replac-
es, incandescent lighting and direct sunlight. Leaving the
transmitter in direct sunlight, for example, will cause it to
read the room temperature higher than it actually is.
NOTE:
To prevent repeated thermo-cycling of the gas
appliance, the sensing unit in the transmitter will only
activate the remote receiver when the temperature change
exceeds 2
°
F (1
°
C) above or below the SET (desired)
temperature.
Setting the Countdown Timer
This remote control system can operate with a built-in
countdown timer when the transmitter is in the ON or
THERMO modes (THERMO or ON must be displayed on
the LCD screen).
• Press and release the TIMER/TIME button on the
transmitter. The word TIMER and 0:15 fl ash on the
screen (see Figure 2.6, Location #2).
• Press the UP and DOWN button to begin advancing
through each of the countdown time options. Available
countdown times are 15 min, 30 min, 45 min, 1 hour, 1 hr
30 min, and each additional half hour up to nine hours.
• To set the TIMER, press the SET button on the
transmitter. If the system is ON, it will remain on until
the “time” has expired. If the system is in the THERMO
mode, it will cycle on and off as the room temperature
requires until the “time” has expired.
NOTE:
When the timer is used in the THERMO mode,
the THERMO operation will discontinue when the “time”
has expired.
Operating the Fan - Operates in ON or THER-
MO mode
This remote control system has the capability of operat-
ing a 110 VAC fan or blower system that may be included
with your gas fi replace. The fan will only operate when the
transmitter is in the ON or THERMO mode. (THERMO or
ON must be displayed on LCD screen).
• To turn fan ON, press and release the FAN button on
the transmitter (see Figure 2.6, Location #9). The fan
will operate at HI speed, and fan blade icon will appear
on LCD screen.
• To change fan speed to MED, press and release FAN
button again. To change fan speed to LO, press and
release FAN button again.
• To turn fan OFF, press and release FAN button again.
Fan blade icon will disappear from LCD screen.
Figure 2.7
Setting Button/Childproof Lockout