Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
13
1.
LOW
- Battery power low. Replace batteries within two weeks.
2.
TIMER
- Indicates time remaining before system shuts off, when timer-
programmed, 9 - hour maximum setting.
3.
MODE
- Indicates operation MODE of system. ON indicates the system is
on, either manually or thermostatically. THERMO indicates the system will
automatically cycle ON/OFF, depending on programmed SET temperature.
OFF indicates the entire system is turned off.
4.
SET
- Indicates desired SET room temperature for THERMO operation.
5.
FLAME
- Single or double Flame/Hi icon indicates burner/valve operational.
6.
CLOCK
- Indicates the current time in AM/PM.
7.
ROOM
- Indicates CURRENT room temperature.
8.
°F
- Indicates degrees Fahrenheit (°C indicates degrees
Celsius).
9.
FAN
- Indicates fan is on or programmed to come on.
Three speed settings are available.
Figure 2.6
Transmitter LCD Display Screen
Matching Security Codes
It may be necessary to program the remote receiver to
the security code of the transmitter upon initial use, if bat-
teries are replaced, or if a replacement transmitter is pur-
chased from your dealer. To program the remote receiver:
• Set the slide button on the receiver to the REMOTE
position.
•
Push the LEARN button (one beep will be heard) on the
top of the remote receiver.
• Then press the MODE button on the transmitter.
Several beeps indicate the transmitter’s code has been
programmed into the receiver. When an existing receiver
is matched to a new transmitter, the new security code
will overwrite the old one.
If you are unsuccessful in matching the security code on
the fi rst attempt, wait 1-2 minutes before trying again.
NOTE:
When the LEARN button is depressed, “beeping”
sounds should be heard. If no “beeping” is heard check to
see that the receiver has 110-120VAC power to it.
Operating Instructions
To operate the system, press the MODE button (Figure
13.4) on the transmitter to select the operational MODE
desired.
• ON indicates the system is on, either manually, timed
or thermostatically.
• THERMO indicates the system will automatically cycle
ON/OFF, depending on programmed set temperature.
• OFF indicates the entire system is turned off.
Transmitter Settings
Flip open the plastic cover on the front of the transmitter
to expose the “SET” buttons.
NOTE:
Flashing numbers on the display indicate the
system is waiting for input, such as using the UP and
DOWN buttons to program a new setting. If no change is
made to fl ashing digits within 15 seconds, the system will
complete the procedure last programmed and reset the
display to its normal state.
Setting the Clock
•
Press and hold the TIMER/TIME button on the transmitter
for more than two seconds. The hour digit(s) will begin
fl ashing (see Figure 13.4, Location #6).
• Press the UP or DOWN button until the desired hour is
displayed in AM or PM.
• After setting the desired hour, press and release the
TIMER/TIME button again to set the minutes; the minute
digits will begin fl ashing.
•
Press the UP or DOWN button until the desired minutes
are displayed.
• Press and hold the TIMER/TIME button again for more
than two seconds. The time digits will cease fl ashing,
indicating the clock has been successfully set. You may
also press the SET button on the transmitter to stop the
time digits from fl ashing and set the time.
MODE
SET
UP
TIMER
DOWN
FAN
FLAME