4–Non-Interactive Commands

Command Summary

SN0054614-00  K

4-47

To save the current adapter firmware preload table to a 

DAT

 file, enter the 

following command:

#

scli -u ( <

hba instance

> | <

hba wwpn

> ) save <

file name

>

Where:

„

<

hba instance

>

 is the adapter instance number of an adapter port.

„

<

hba wwpn

>

 is the world wide port name (WWPN) of an adapter port.

„

<

file name

>

 is the name of the firmware preload table

 DAT 

file.

-v 

(Display Version)

To show the version number of the SANsurfer FC/CNA HBA CLI tool, type:

#

scli -v

The system shows the following information:

SANsurfer FC/CNA HBA CLI
v1.

x

.

x

 Build 

x

Copyright 2003-2009 QLogic Corp.
All rights reserved.
Command Line QLogic FC Host Bus Adapters.
Build Type: Release
Build Date: 

xx

/

xx

/

xxxx

 

xx

:

xx

:

xx

 AM

-vp 

(Virtual Port)

To list all virtual ports on a physical adapter port, type:

#

scli -vp (<

hba instance

> : <

hba wwpn

>) list all

Where:

To list a specific virtual port on a physical adapter port, type:

NOTE:

This option is valid only in non-interactive mode.

hba instance

= Adapter number (use 

-g

 command to find)

hba wwpn

= World wide port name of the adapter

vport wwpn

= World wide port name of the virtual port

vport hex

= World wide port name of the virtual port with the two 

hex digits in byte three supplied by the user

Summary of Contents for QLA2 Series

Page 1: ...SN0054614 00 K SANsurfer FC CNA HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters...

Page 2: ...ision History Revision A August 20 2004 Revision B September 28 2005 Revision C June 7 2006 Revision D October 1 2006 Revision E February 1 2007 Revision F February 29 2008 Revision G June 30 2008 Rev...

Page 3: ...ed new message passing interface MPI options for the Utilities menu Update MPI Config Table on page 3 71 Save MPI Config Table on page 3 71 Updated loopback and read write buffer test descriptions and...

Page 4: ...iv SN0054614 00 K SANsurfer FC CNA HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Notes...

Page 5: ...g Systems 1 3 System Requirements 1 4 Hardware Requirements 1 4 Software Requirements 1 5 Unsupported Features 1 5 Downloading the Installation Package 1 6 Installing SANsurfer FC CNA HBA CLI 1 7 Wind...

Page 6: ...eral Information Menu Command Line Option g 3 4 Host Information Command Line Option g 3 4 Host Topology Command Line Option tp topology 3 5 Display Host Topology Command Line Option tp topology 3 6 S...

Page 7: ...t All Adapters 3 42 Individual Target 3 42 Individual LUN 3 43 All Targets 3 43 All Target s 3 44 All LUN s 3 45 Target Link Speed or iiDMA Settings Menu Command Line Option q 3 47 Configuring the iiD...

Page 8: ...3 62 Utilities Menu 3 64 Update Flash Per Adapter Port or All HBAs Command Line Option b 3 65 Save Flash Per Adapter Port Command Line Option b and Reserved Word save 3 65 Update HBA Parameters Per A...

Page 9: ...85 Transceiver Details General 3 86 Transceiver Details Details 3 86 Statistics Menu Command Line Options gs and ls 3 89 HBA Statistics Monitoring Command Line Option gs 3 90 Configuration 3 90 Show...

Page 10: ...tion 4 4 Command Summary 4 5 a View or Toggle Beacon Status 4 6 b Save or Update the Flash BIOS or FCode 4 7 c Show Parameter Settings 4 8 cna FCoE Utilities Menu for QLx81xx Adapters 4 8 d Update Dev...

Page 11: ...ing Info 4 38 pa Define Port Alias 4 40 pl Show Add and Delete Persistent Names 4 41 q View or Set Target Link Speed 4 42 qos QoS Menu 4 43 r Update HBA Parameters 4 44 s Silent Mode 4 45 t Display Ta...

Page 12: ...A 14 HBA Statistics Command Line Option gs A 14 HBA Alias Command Line Option ha A 15 HBA Port Alias Command Line Option pa A 15 HBA Transceiver Details Command Line Option dm A 16 Host Topology Comm...

Page 13: ...lias Command Line Option ha B 18 HBA Port Alias Command Line Option pa B 18 HBA Transceiver Details Command Line Option dm B 20 Host Topology Command Line Option tp B 25 Display FCoE Information B 27...

Page 14: ...SP2312 3 68 3 9 Template Supported Parameter Settings for QLA23xx Adapters ISP2322 3 68 3 10 Adapter Diagnostics Configuration Settings 3 81 3 11 Adapter Port Statistics Options 3 91 3 12 Statistics L...

Page 15: ...condensed version of the SANsurfer FC HBA Manager graphical user interface GUI which manages both local and remote hosts SANsurfer FC CNA HBA CLI can be operated in two modes Interactive mode menu dr...

Page 16: ...L files created with the x1 command line option Appendix B XML Format 2 provides explanations and examples of XML files created with the x2 command line option Appendix C Error Exit Return Codes lists...

Page 17: ...the latest firmware and product updates For information on the Virtual Menu see Virtual Menu for Adapter Instance on page 3 98 In 3 Interactive Commands a breadcrumbs line follows most command headin...

Page 18: ...the Education Training tab at the left The QLogic Global Training Portal offers online courses certification exams and scheduling of in person training Technical certification courses include installa...

Page 19: ...HBA CLI on page 1 7 Uninstalling SANsurfer FC CNA HBA CLI on page 1 21 Prerequisites Before you run SANsurfer FC CNA HBA CLI ensure that the following requirements are met The adapters must be install...

Page 20: ...formation see Unsupported Features on page 1 5 NOTE If SANsurfer FC CNA HBA CLI detects an unsupported adapter the following message appears where X is the adapter instance number and YYYYYYY is the a...

Page 21: ...bit Intel IA64 Intel 64 AMD64 Red Hat RHEL AS ES 4 5 32 bit 64 bit Intel IA64 Intel 64 AMD64 Red Hat RHEL AS ES 4 0 32 bit 64 bit Intel IA64 Intel 64 AMD64 Red Hat RHEL AS ES 3 0 32 bit 64 bit Intel x...

Page 22: ...1 8 MHz or greater with 512 MB of memory FC devices such as disks and RAID subsystems QLogic FC adapters SANsurfer FC CNA HBA CLI supports most FC devices For a complete list of devices that support f...

Page 23: ...ng on your system not all SANsurfer FC adapter features are available Features Not Available When Running Windows Driver with NPIV Enabled When running the driver with NPIV enabled on Windows the foll...

Page 24: ...cs Driver settings Host topology Link status Loopback test Features Not Available When Running VMware Driver When running the VMware driver on a Linux OS the following features are not available with...

Page 25: ...load the file Installing SANsurfer FC CNA HBA CLI Follow the installation instructions in the section that corresponds to your operating system OS Windows Installation on page 1 8 Linux Installation o...

Page 26: ...nd Line Installation on page 1 12 Standard GUI Installation Follow these steps to install SANsurfer FC CNA HBA CLI on a Windows operating system using the standard GUI method To install SANsurfer FC C...

Page 27: ...oval Installing SANsurfer FC CNA HBA CLI SN0054614 00 K 1 9 After the install package is loaded the Welcome dialog box appears as shown in Figure 1 3 Figure 1 3 Welcome Dialog Box 2 Read the informati...

Page 28: ...Dialog Box 3 In the Choose Destination Location dialog box do one of the following To select the destination location in the dialog box click Next recommended The default location for a Windows system...

Page 29: ...0 K 1 11 The Ready to Install the Program dialog box appears as shown in Figure 1 5 Figure 1 5 Ready to Install the Program Dialog Box 4 Read the information and then click Install The Setup Status di...

Page 30: ...If you want to see more information about SANsurfer FC CNA HBA CLI select the I would like to view the README file check box If you want to start SANsurfer FC CNA HBA CLI select the I would like to l...

Page 31: ...Installation Parameters Parameter Meaning Description r Record modea To run the SANsurfer FC CNA HBA CLI installation package in silent mode first run scli 1 x x xx windows exe with the r parameter to...

Page 32: ...site or the SANsurfer for FC and FCoE Adapters CD ROM download to your local machine following file scli x xx xx xx i386 rpm gz Where x xx xx xx specifies the current version of SANsurfer FC CNA HBA C...

Page 33: ...he steps in one of these sections Solaris SPARC 8 9 10 Installation on page 1 15 Solaris x86 9 and 10 Installation on page 1 17 Solaris SPARC 8 9 10 Installation Follow these steps to install SANsurfe...

Page 34: ...stance QLScli from space chuynh scli qlogic Solaris pkgs x QLogic SANsurfer FC CNA HBA CLI HBA Configuration Utility sparc x xx xx Build xx QLogic Corporation Executing checkinstall script Using as th...

Page 35: ...rfer for FC and FCoE Adapters CD ROM download to a temporary directory for example tmp on your machine the following file scli x xx xx xx x86 Solaris pkg 2 To decompress the file type the following un...

Page 36: ...installed Verifying disk space requirements Checking for conflicts with packages already installed Checking for setuid setgid programs verifying class none Executing postinatall script Installation of...

Page 37: ...NA HBA CLI on a Macintosh using the command line method To install SANsurfer FC CNA HBA CLI on Macintosh command line 1 Download the SCLI install package for Mac OS x compressed tar file to a local di...

Page 38: ...installer Upgrading volume mounted at installer The upgrade was successful VMware Installation Follow these steps to install SANsurfer FC CNA HBA CLI on a system running VMware ESX 3 5 To install SANs...

Page 39: ...tall SANsurfer FC CNA HBA CLI on Windows using the GUI method To uninstall SANsurfer FC CNA HBA CLI on Windows GUI 1 From the Control Panel click Add or Remove Programs 2 Highlight SANsurfer FC CNA HB...

Page 40: ...all SANsurfer FC CNA HBA CLI To uninstall SANsurfer FC CNA HBA CLI on Solaris SPARC 8 9 and 10 1 Type the following pkgrm QLScli 2 The program shows the package name and a script warning asking whethe...

Page 41: ...g whether to continue the uninstall process For example The following package is currently installed QLSclix QLogic SANsurfer FC CNA HBA CLI HBA Configuration Utility x86 1 x x Build xx Do you want to...

Page 42: ...fer FC CNA HBA CLI delete its folder and any references to the SANsurfer installer package s in the Library Receipts directory For example rm rf Library Receipts scli x x x x pkg VMware Uninstall To u...

Page 43: ...vers this interface Non interactive command line The CLI starts executes the functions defined by the list of parameters provided and then terminates Use this mode to run SANsurfer FC CNA HBA CLI from...

Page 44: ...owing SANsurfer FC CNA HBA CLI v1 x x Build xx Main Menu 1 General Information 2 HBA Information 3 HBA Parameters 4 Target LUN List 5 Target Link Speed or 5 iiDMA Settings 6 Target Persistent Bindings...

Page 45: ...eed or iiDMA Settings The Virtual menu selection is available only on Windows systems running with a driver that supports NPIV N_Port ID virtualization The QoS menu selection is available only on Wind...

Page 46: ...urfer FC CNA HBA CLI accepts the notation with and without the dash Hexadecimal values can be uppercase or lowercase The following input formats are both valid for the WWNN and WWPN 20 00 00 E0 8B 01...

Page 47: ...dm 12 12 12 Transceiver details dm Display Diag nostics Monitoring Info on page 4 10 e 8 8 8 Boot device settings e Boot Device View Select Dis able on page 4 11 f Input from a file f Input Parame te...

Page 48: ...al Informa tion or VPD Infor mation for One or All HBAs on page 4 20 kl 12 12 12 Loopback test kl Loopback Test on page 4 20 kr 12 12 12 Read write buffer test kr Run Read Write Buffer Test on page 4...

Page 49: ...es pl Show Add and Delete Persis tent Names on page 4 41 q 5 5 5 Target link speed q View or Set Target Link Speed on page 4 42 qos 15 Quality of service qos QoS Menu on page 4 43 r Save update NVRAM...

Page 50: ...on page 4 46 u 10 10 10 Update or save firm ware preload area u Firmware Area Update Save on page 4 46 v Show version v Display Ver sion on page 4 47 vp 14 14 Virtual portsc vp Virtual Port on page 4...

Page 51: ...For example a QLA2462 has two ports called HBA port 1 and HBA port 2 adapter instance adapter instance number or adapter port instance When you install adapter in a system with other adapters each ad...

Page 52: ...eventually translates to IOPS or allocating bandwidth to them Setting the QoS by bandwidth lets you allocate up to 80 of the number of gigabits per second Gbps transmission speed of the physical port...

Page 53: ...Menu Command Line Option i on page 3 19 HBA Parameters Menu on page 3 24 Target LUN List Menu Command Line Options t and l on page 3 36 Target Link Speed or iiDMA Settings Menu Command Line Option q...

Page 54: ...e Main Menu appears as follows Main Menu 1 General Information 2 HBA Information 3 HBA Parameters 4 Target LUN List 5 Target Link Speed or 5 iiDMA Settings 6 Target Persistent Bindings 7 Selective LUN...

Page 55: ...on 1 to open the General Information menu 2 to open the Host Topology menu and then 2 again to see the Save As Txt File options The following shows the breadcrumbs example NOTES Selections on the Main...

Page 56: ...Topology see Host Topology Command Line Option tp topology on page 3 5 Report see Generate Report Command Line Option z on page 3 10 Refresh see Refresh on page 3 19 Host Information Command Line Opti...

Page 57: ...C0551C34679 Port 1 WWPN 21 00 00 E0 8B 1F 9D F0 SN FFC0519U93213 HBA Instance 4 Online Port 2 WWPN 21 01 00 E0 8B 3F 9D P0 SN FFC0519U93213 HBA Instance 5 Loop down HBA Model QLA21O SN C655417 Port 1...

Page 58: ...switch Interconnect element switch Type Switch or adapter World wide name Domain ID Management ID IP address Model Symbolic name Serial number MAC address Firmware version Port count Beacon status If...

Page 59: ...ator Node Name Port Name Vendor ID Product ID if applicable Product Revision if applicable Product Serial Number if applicable Adapter Model if applicable Adapter Serial Number if applicable Adapter A...

Page 60: ...Firmware Version Port Count 8 Beacon Status Unsupported Port Information Physical Port Number 1 Port Name 20 00 00 C0 DD 00 6A 9F Port state Offline Port Type F_Port TX Port Type Electrical EL Port Mo...

Page 61: ...laser SN 850nm Port Module Type GBIC Attached Port Target Initiator ISL Node Name 20 00 00 E0 8B 03 55 7C Port Name 21 00 00 E0 8B 03 55 7C Vendor Id QLogic Corporation HBA Model 2200 HBA Serial Numb...

Page 62: ...with options to Save as XML Format 1 Save as XML Format 2 Save As XML File Format 1 Command Line Option x 1 General Information 2 Host Topology 3 Save As XML File 1 Save As XML File format 1 The syst...

Page 63: ...n including SANsurfer FC CNA HBA CLI header Version and build Adapter header Host name OS type OS version SDM API version Adapter Model Serial Number Port number Port WWPN Adapter instance Status onli...

Page 64: ...actual VPD information Product Identifier Part Number Serial Number Misc Information for example PCI and PCI X speeds Manufacturing ID EFI Driver Version Firmware Version BIOS Version Windows and Lin...

Page 65: ...ance Adapter Part Number Port Number WWPN Port ID Driver Settings repeats for each adapter instance Driver Settings Group Persistent Persistently bound Plus New targets Persistently bound targets only...

Page 66: ...vice Vendor ID Device Product ID Serial Number Device Port Name Device Port ID Boot Device Settings Selectable Boot Primary Boot Port Name Primary Boot Port Address Alternate 1 Boot Port Name Alternat...

Page 67: ...Model QLA2462 SN FFC0551D59564 Port 1 WWPN 21 00 00 E0 8B 85 8C 7C HBA instance 4 Loop down Port 2 WWPN 21 01 00 E0 8B A5 8C 7C HBA instance 5 Online Total QLogic HBA s 3 Time and date Tue Nov 20 16...

Page 68: ...p ID Disabled Enable FC Tape Support Enabled Execution Throttle 16 Login Retry Count 8 Enable LIP Reset Disabled Port Down Retry Count 30 Enable LIP Full Login Enabled Link Down Timeout seconds 0 Enab...

Page 69: ...E4 Product Type Disk LUN Count s 1 Status Online LUN 0 Product Vendor SEAGATE Product ID ST136403FC Product Revision FF5F LUN 0 Size 33 92 GB Type SBC 2 Direct access block device e g magnetic disk W...

Page 70: ...01 00 E0 8B 23 55 7C PortID 11 06 00 Device Vendor ID SEAGATE Device Product ID ST136403FC Serial Number LT06464600001011HGGH Device Port Name 21 00 00 20 37 1A 6B CF Device Port ID 11 01 E4 Enable T...

Page 71: ...system shows the report information for all adapters See Generate Report Per Adapter Port on page 3 11 in which data repeats for every adapter Refresh 1 General Information 4 Refresh This selection r...

Page 72: ...All HBAs 8 Return to Previous Menu In the following example the QLE8042 adapter includes an FCoE engine HBA Information Menu HBA Model QLE2562 1 Port 1 WWPN 21 00 00 1B 32 16 C3 EE Online 2 Port 2 WW...

Page 73: ...ormation Command Line Option i 2 HBA Information n Port Number 1 HBA Information This option produces the same HBA Information Menu available from the General Information Report menu See Generate Repo...

Page 74: ...r for the adapter model and then press ENTER 5 Create modify or delete the adapter alias as follows a To create or modify an the adapter alias type a symbolic name maximum 100 characters at the HBA Al...

Page 75: ...elect a port number from the Port Alias Menu the CLI prompts you to enter a Port Alias as follows Port Alias _ To keep the current port alias enter the number for Cancel and then press ENTER To change...

Page 76: ...he Information menu shows the same adapter Information available from the General Information Menu See Generate Report Per Adapter Port on page 3 11 2 HBA Information n All HBAs 3 VPD The VPD menu sho...

Page 77: ...8 All HBAs 9 Return to Previous Menu The following example of an HBA Parameters Menu includes adapter QLE8042 with an FCoE engine see HBA Parameters Per FCoE Engine HBA Model QLE2562 1 Port 1 WWPN 21...

Page 78: ...ttle Login Retry Count Enable LIP Reset Port Down Retry Count Enable LIP Full Login Link Down Timeout seconds Enable Target Reset LUNs Per Target Enable Receive Out Of Order Frame Configure HBA Parame...

Page 79: ...3 See table note 1 DataRate DR 0 4 See table note 2 EnableBIOS EB 0 1 See table notes 3 4 EnableExtendedLogging EL 0 1 See table notes 3 4 EnableFCTape EF 0 1 See table note 3 EnableHardLooplD HL 0 1...

Page 80: ...Interrupt when Interrupt Delay Timer expires 6 Interrupt when Interrupt Delay Timer expires or no active I O Connection Options 3 HBA Parameters 1 Port Number 2 Configure HBA Parameters n Connection O...

Page 81: ...ze menu From it you can select Frame Size 512 Frame Size 1024 Frame Size 2048 Type the number for the frame size you want and then press ENTER Hard Loop ID 3 HBA Parameters N Port Number 2 Configure H...

Page 82: ...le Fibre Channel Tape support Type the number you want and then press ENTER Operation Mode 3 HBA Parameters N Port Number 2 Configure HBA Parameters n Operation Mode This option shows the Operation Mo...

Page 83: ...LIP Full Login 3 HBA Parameters N Port Number 2 Configure HBA Parameters n Enable LIP Full Login This choice gives you the option to enable or disable LIP Full Login Link Down Timeout 3 HBA Parameter...

Page 84: ...BA parameters may render the HBA inoperable If you currently have boot device information set up in the HBA parameters updating the HBA parameters from a file may result in changing that information I...

Page 85: ...t instance as shown in the following example FCoE Port Selection Menu FCoE Engine QLE8042 Desc QLE8042 Mercury CNA 1 Port 0 2 Port 1 3 Return to Previous Menu Note 0 to return to Main Menu Enter Selec...

Page 86: ...he port is configured as an access port packets are untagged and do not contain a VLAN tag Pause Type 3 HBA Parameters n FCoE Engine 2 Configure FCoE Parameters n Pause Type This option shows the Paus...

Page 87: ...Priority Flow Control type length value TLV this parameter is configured on the adapter When not connected to a DCBX enabled peer or before receipt of a Priority Flow Control TLV on setting of this pa...

Page 88: ...king to a switch that does not support DCBX HBA Parameters All HBAs 3 HBA Parameters n All HBAs When you select this option the parameters listed in HBA Parameters Per Adapter Port on page 3 25 appear...

Page 89: ...Vendor SEAGATE Product ID ST318453FC Product Rev 0006 Serial Number 3JA9TN7600007517T6P1 Node Name 20 00 00 11 C6 2D 5B F9 Port Name 22 00 00 11 C6 2D 5B F9 Port ID 02 0A DC 2 Disk Online Table 3 2 Ta...

Page 90: ...et the LUN List Menu for that target appears It includes a list of all LUNs on that target and the following information for each LUN LUN Number Vendor Product ID Port Name Port ID All LUN s Here is a...

Page 91: ...LN OS LUN Name on Solaris and Linux For example Product Vendor HP Product ID MSA VOLUME Product Revision 6 68 LUN 8 Size 4 88 GB Type SBC 2 Direct access block device e g magnetic disk WWULN 60 05 08...

Page 92: ...or HP Product ID MSA VOLUME Product Revision 6 68 LUN 8 WWULN 60 05 08 B3 00 90 8D B0 AF 57 A1 B0 88 40 00 20 OS LUN Name dev sdh Persistent LUN Name 2 Add To add persistent binding for the LUN select...

Page 93: ...53 50 00 00 00 00 00 00 00 1C OS LUN Name dev sdbh dev sg59 Persistent LUN Name test1 Persistent device name of LUN 28 TID 1 has been deleted Please reboot or run udevtrigger command for the changes...

Page 94: ...s the Target List Menu for All HBAs Individual Target Individual LUN All Target s All LUN s Individual Target 4 Target LUN List N All HBAs 1 Individual Target This choice shows the Target List Menu fo...

Page 95: ...target information appears Path Target Device ID Product Vendor Product ID Product Revision Node Name Port Name Product Type LUN Count s Status Here is an example of the Target information Path 0 Tar...

Page 96: ...ct access block device e g magnetic disk WWULN 20 00 00 0C 50 68 1E 9A Hit RETURN to continue All Target s 4 Target LUN List n Port Number 3 All Target s This choice shows information for all targets...

Page 97: ...00 00 20 37 1A 6B CF Port ID 11 01 E4 Product Type Disk LUN Count s 1 Status Online And so forth All LUN s 4 Target LUN List n Port Number 3 All LUN s When you select this option SANsurfer FC CNA HBA...

Page 98: ...Target information repeats for each target Here is an example of the All LUNs information for Linux Product Vendor HITACHI Product ID HUS103073FLF210 Product Revision FA16 LUN 0 Size 68 37 GB Type SB...

Page 99: ...3 Port 1 WWPN 21 00 00 E0 8B 05 CB D8 Loop down 4 Port 2 WWPN 21 01 00 E0 8B 25 CB D8 Online HBA Model QLA2462 5 Port 1 WWPN 21 00 00 E0 8B 1P 9D P0 Online 6 Port 2 WWPN 21 01 00 E0 8B 3P 9D P0 Loop...

Page 100: ...ct an apply different iiDMA update to each device attached to this adapter 4 To use Basic Configuration a Select the adapter b Select the iiDMA from the intelligent interleave factor speed list 1 Gbps...

Page 101: ...target s The following is returned The iiDMA settings have been saved to selected target s To exit without making any changes select Return to Previous Menu HBA Port Instance 5 Target Link Speed Targe...

Page 102: ...A Port ID 11 0A E2 Max Target Link Rate 4 Gbps m Disk Vendor SEAGATE Product ID ST318453FC Product Rev 0006 Serial Number 3JA9TQE0000724966ZK Port Name 22 00 00 11 C6 2D 5A 3F Port ID 02 0A E4 Max Tar...

Page 103: ...the Target Link Menu the Target Link Speed Menu Advanced appears It includes the link speed options The options vary according to the adapter in use For example 1 Gbps 2 Gbps 4Gbps 8 Gbps Type the nu...

Page 104: ...ll HBAs 1 Advanced Configuration This option shows the Target Link Speed Menu Advanced for All HBAs This menu lists all targets on all adapters and shows information about each target Target Type Targ...

Page 105: ...e 4 Gbps p Apply Changes to Selected Target s Target Link Speed All HBAs Advanced Configuration 5 Target Link Speed 2 All HBAs 1 Advanced Configuration 1 n Link speed When you select an adapter to set...

Page 106: ...fer FC CNA HBA CLI shows the Target Persistent Binding menu listing standard adapter port instances see HBA Port Instance on page 3 49 where you can select an individual adapter port or All HBAs The f...

Page 107: ...1 n Target Persistent Binding HBA Instance n 1 Display Configuration When you select the Display Configuration option the following information appears Or the message No target persistent binding conf...

Page 108: ...Target ID m Disk 2 on QLA2462 HBA Instance 1 Vendor SEAGATE Product ID ST318453FC Port Name 22 00 00 11 C6 2D 5A 3F Port ID 11 0A E2 Bind No Target ID n Disk Vendor SEAGATE Product ID ST318453FC Port...

Page 109: ...Display Configuration Bind Target s Unbind Target s Display Target Persistent Binding 6 Target Persistent Binding p All HBAs 1 Display Configuration When you select the Display Configuration option th...

Page 110: ...n is not available for the selected LUN the following message appears Configuration not permitted Device s either not present or not persistently bound HBA n Selective LUNs All HBAs 7 Selective LUNs 1...

Page 111: ...C CNA HBA CLI lists the disks on the selected adapter port and shows the current configuration of each Select the number for the disk you want to configure and then press ENTER to continue You can the...

Page 112: ...he Boot Device Settings menu for adapter instance m You can choose to Display Boot Device s Configure Boot Device s Boot Device s Per Adapter Port 8 Boot Device n Port Number 1 Display Boot Device s W...

Page 113: ...2 Configure Boot Device s When you select this option SANsurfer FC CNA HBA CLI shows the Boot Device Settings menu for adapter instance m including the adapter model number and details about its spec...

Page 114: ...1 Save Configuration When you select this option the CLI shows the Save Configuration menu Proceed Cancel Boot Device s All HBAs 8 Boot Device 1 All HBAs When you select this option SANsurfer FC CNA...

Page 115: ...s Only option available for all drivers Present targets with driver default option available for failover driver only Bind by World Wide Port Name option available for all drivers except Macintosh dr...

Page 116: ...see page 3 66 HBA Parameters Templates see page 3 66 Update Driver Windows only see page 3 69 Update Firmware Preload Table 8Gb adapters only see page 3 69 Save Firmware Preload Table 8Gb adapters onl...

Page 117: ...pdating Adapter flash NIC Boot Code Updating Adapter flash NIC MPI FW Updating Adapter flash FC Boot Code FW Updating Adapter flash uncompressed FW Updating Adapter flash FC VPD Updating Adapter flash...

Page 118: ...HBA Parameters When you select the Save HBA Parameters option SANsurfer FC CNA HBA CLI prompts you to select an adapter You then enter a file name to save the parameters for that adapter HBA Parameter...

Page 119: ...d adapters by ISP number NOTE Settings that are effected by the template apply only to the ISP 2300 2310 2312 2Gb adapters and the ISP2422 2432 4Gb adapters Table 3 5 Template Supported Parameter Sett...

Page 120: ...ding Loop ID Search 0 1 0 0 Maximum LUNs Per Target 128 256 0 8 Port Down Retry Count 30 45 30 30 Link Down Timeout 30 45 30 0 Table 3 8 Template Supported Parameter Settings for QLA23xx Adapters ISP2...

Page 121: ...d then enter a file name INF ZIP or EXE with which to update the driver for that port Update Firmware Preload Table 10 Utilities n Update Firmware Preload Table The preload table is basically a list o...

Page 122: ...e Warning Please update the HBA flash region with extreme care Incorrectly updating the flash region may render the HBA inoperable Do you want to proceed with the operation 1 Yes 2 No Enter Selection...

Page 123: ...irmware When you select this option from the Utilities menu SANsurfer FC CNA HBA CLI prompts you to select either an 8Gb adapter port QLx81xx or All HBAs to update The CLI displays the current version...

Page 124: ...e Area Update The Firmware Area Update operation takes a firmware preload table dat file and writes the data to the Flash on the card This option is visible only if you have selected an 8Gb adapter To...

Page 125: ...A companion file with DEF file extension must be present to insure that file comparision during DVT testing will pass Revision History REV DATE WHO ER DESCRIPTION OF CHANGE a 08 24 07 kd xxxxx Initia...

Page 126: ...menu select the number for the Firmware Area Save option The following menu is shown for example Firmware Area Save Menu HBA Model QLE2562 1 Port 1 WWPN 21 00 00 1B 32 16 18 EE Loop Down 2 Port 2 WWPN...

Page 127: ...1 Locate HBA When you select this option SANsurfer FC CNA HBA CLI shows the HBA Beacon Menu that lists all adapter ports Select any port and then press ENTER to toggle the Beacon LED for that port Lo...

Page 128: ...On Active Beacon Selected Target s 11 Beacon 2 Locate Target s 3 Beacon Selected Target s When you select the Beacon Selected Target s option SANsurfer FC CNA HBA CLI shows a list of the targets assoc...

Page 129: ...4Gb and 8Gb only Test Results Test results for loopback and read write buffer tests may include the following Loopback test results Test Status CRC Error Disparity Error Frame Length Error Read Write...

Page 130: ...pback connector is used In addition some driver versions do not require a loopback connector The test evaluates the ports transmit and receive transceivers on the adapter More specifically the loopbac...

Page 131: ...back connector do the following a Disconnect the cable from the appropriate adapter connector b Install the loopback connector on the adapter connector 4 Follow the steps in either Start Diagnostic Te...

Page 132: ...stored immediately Restoring default settings done Configure Test Parameters Loopback 12 Diagnostics n Port Number 1 Loopback Test 3 Configure Test Parameters Select the Configure Test Parameters opti...

Page 133: ...e note 5 LoopbackType LT 0 1 2 See table note 6 Table Notes 1 DataPattern is the test pattern in hexadecimal format user defined pattern hex or random pat tern Hex Binary 00 00000000 55 01010101 5A 01...

Page 134: ...esc QLE2562 PCI Express to 8Gb FC Dual Channel 1 10 bit Internal Loopback 2 1 bit Serial Loopback 3 External Loopback Current 4 Return to Previous Menu Start Diagnostic Test Loopback 12 Diagnostics n...

Page 135: ...en the adapter port and the target Configure Test Parameters Read Write The read write buffer test must be run on a disk device Before running the read write buffer test verify that the adapter port i...

Page 136: ...arameters in Step 4 the Diagnostic Menu R W Buffer appears For example 1 Data Pattern 2 Data Size 3 Number of Test s 4 Test Increment s 5 On Error Policy 6 Enable Disable Test Continuously 7 Enable Di...

Page 137: ...Ignore Test Continuous OFF Diagnostics Read Write Buffer Test Result Hit ENTER to abort Iter No Data Pattern Status 7219 F8 B8 7D 52 D1 0B 28 A2 Success 7220 Error Data mis compare C5 01 00 1 Expecte...

Page 138: ...d Yes Temperature Voltage Tx Bias Tx Power Rx Power C V mA mW mW Value 35 84 3 33 8 04 0 5835 0 6172 Status Normal Normal Normal Normal Normal High Alarm 78 00 3 70 11 80 0 8318 1 0000 High Warning 73...

Page 139: ...Signal Loss as defined in SFP MSA 0x1 Signal Loss inverted from SFP MSA 0x0 TX_FAULT signal implemented 0x1 TX_DISABLE implemented disables serial o p 0x1 RATE_SELECT implemented 0x0 BR max 0x00 BR mi...

Page 140: ...Low Alarm 0x09d0 TX Signal Power High Warning 0x1ba7 TX Signal Power Low Warning 0x0c5a RX Signal Power High Alarm 0x2710 RX Signal Power Low Alarm 0x0064 RX Signal Power High Warning 0x1f07 RX Signal...

Page 141: ...gh Alarm 0x0 TX Signal Power Low Warning 0x0 TX Signal Power High Warning 0x0 TX Bias Low Warning 0x0 TX Bias High Warning 0x0 Vcc Low Warning 0x0 Vcc High Warning 0x0 Temp Low Warning 0x0 Temp High W...

Page 142: ...or the HBA Statistics option and then press ENTER 3 From the HBA Statistics Menu type the number for the Configuration option and then press ENTER The HBA Statistics Settings Menu contains the followi...

Page 143: ...tics to a file select Log to File and then press ENTER Type the name of a csv file to save to and then press ENTER Table 3 11 shows the values for the adapter port statistics options Current Settings...

Page 144: ...ration value and returns the following message Manual Poll updated Set Rate 13 Statistics 1 HBA Statistics 1 Configuration 4 Set Rate The system prompts you to enter a value for the sampling rate the...

Page 145: ...lect an adapter port Type the number for the port and then press ENTER The adapter statistics for that port are shown For example HBA Instance 0 2200 Port 1 WWPN 21 00 00 E0 8B 03 55 7C PortID 00 00 E...

Page 146: ...Status 1 Configuration 1 Current Settings Select the Current Settings option to have the system show the current link status settings for AutoPoll AP SetRate SR LogToFile LF Restore Default 13 Statist...

Page 147: ...iteration value and returns the following message Manual Poll updated Set Rate 13 Statistics 2 Link Status 1 Configuration 4 Set Rate The system prompts you to enter a value for the sampling rate the...

Page 148: ...Statistics Menu appears Type the number for the Link Status option and then press ENTER 3 The Link Status Menu appears Type the number for the Show Link Status option and then press ENTER 4 You are p...

Page 149: ...V capable Windows driver with QLogic s SANsurfer FC CNA HBA CLI to create delete and manage virtual ports You can deploy and migrate virtual ports in conjunction with virtual machines VMs in your Sola...

Page 150: ...e that this feature is supported only with an NPIV enabled driver Virtual Menu for Adapter Instance 14 Virtual 1 Virtual Menu When you select this option the Virtual Port Menu appears with the followi...

Page 151: ...3 List Virtual Ports When you select this option the menu of virtual ports on this physical adapter port appears showing List Virtual Ports including for each Instance Number Virtual Port Number WWPN...

Page 152: ...nu Auto Generate 14 Virtual 1 Virtual Menu 3 Create a Virtual Port 1 Auto Generate When you select this option the system creates a virtual port on this adapter s physical port and reports the WWPN of...

Page 153: ...l ports by either setting priorities or allocating bandwidth SANsurfer FC CNA HBA CLI provides an easy to use interface that lets you assign QoS to virtual ports by either setting priorities or alloca...

Page 154: ...del QMH2562 1 Port 1 WWPN 50 06 0B 00 00 C2 AE 00 Online 2 Port 2 WWPN 50 06 0B 00 00 C2 AE 02 Online 3 Return to Previous Menu Note 0 to return to Main Menu Enter Selection 1 Select one of the online...

Page 155: ...r or not that virtual port is currently Enabled and Unlocked and then press ENTER 2 If the virtual port is already enabled and unlocked proceed to Step 3 Otherwise a The virtual port must be Enabled t...

Page 156: ...wo different types of bandwidth for virtual ports Bandwidth Speed specifies that the maximum bandwidth speed of all virtual ports cannot exceed the maximum actual connection speed For details see QoS...

Page 157: ...ps is reserved to handle non QoS applications or VMs QoS Bandwidth Speed Menu 15 QoS n Port number 2 QoS Bandwidth 1 Bandwidth Speed The QoS Bandwidth Speed Menu lists all virtual ports for the select...

Page 158: ...elect either 1 for Mbps or 2 for Gbps 5 The Enter Bandwidth Speed prompt shows the allowable range and current speed in square brackets Type a new speed value and then press ENTER The QoS Bandwidth Sp...

Page 159: ...vPort enter 2 for the Lock Unlock QoS Settings option and then 2 again to Unlock the vPort 3 On the QoS Bandwidth Percentage Menu select the Modify QoS Settings option 4 The Enter Bandwidth Percentage...

Page 160: ...FC services such as WWNs zoning and LUN masking The FCoE menu is available only for the QLE80xx QLE81xx and QMI81xx adapters When you select FCoE from the main menu SANsurfer FC CNA HBA CLI displays a...

Page 161: ...e Stats Select the Network Interface Stats option to show network statistics link NSL port statistics for one of the available port numbers The following example shows the output of that option NSL Po...

Page 162: ...ed Unicast Packets 0 Number of Received Multicast Packets 0 Number of Received Broadcast Packets 0 Number of Received Packets with VLAN tag 0 Number of Received Oversized Packets with Good CRC 0 Numbe...

Page 163: ...option to show information similar to the following example LogID 9 LogName DCX 000 00 00 00 250 dcx_initialize DCX enabled and initialized FCoE Utilities Menu for QLx81xx Adapters Command Line Option...

Page 164: ...apter is displayed as shown in the following example HBA Instance 0 QLE8142 Port 1 WWPN 21 00 00 C0 DD 12 0D ED PortID C5 02 20 General Info VN Port MAC Address 0E FC 00 C5 02 20 VLAN ID 1002 Max Fram...

Page 165: ...mitter sends data at a higher rate than the receiver In such situations the receiver sends a PAUSE frame to the transmitter and the transmitter suspends transmission for the specified time Standard ap...

Page 166: ...to a DCBX enabled peer or before receiving a port CoS value the port CoS TLV is based on this parameter setting Priority Txt Mode Specifies the priority mode for data transfer as one of the following...

Page 167: ...e current Sampling Rate in seconds To change the sampling rate enter a numeric value between 5 and 30 Set Details 16 FCoE 3 DCE Statistics 4 Set Details Select the Set Details option to view the curre...

Page 168: ...Receive Packets 7038642 Receive Packets Ok 1447366 Receive Broadcast Packets 157285 Receive Multicast Packets 1105617 Receive Unicast Packets 184464 Receive Undersize Packets 0 Receive Oversize Packe...

Page 169: ...Priority 0 0 Transmit Packets Priority 1 0 Transmit Packets Priority 2 0 Transmit Packets Priority 3 123851 Transmit Packets Priority 4 0 Transmit Packets Priority 5 0 Transmit Packets Priority 6 0 Tr...

Page 170: ...meters Details for CNA Instance 0 QLE8142 Fri May 01 14 27 08 2009 DCBX TLV Type Length Value Data DCBX Parameter Type and Length DCBX Parameter Length 13 DCBX Parameter Type 2 DCBX Parameter Informat...

Page 171: ...id Yes Reserved 0 DCBX Parameter Data Priority Group ID of Priority 1 0 Priority Group ID of Priority 0 0 Priority Group ID of Priority 3 1 Priority Group ID of Priority 2 0 Priority Group ID of Prior...

Page 172: ...elect the Raw option TLV data appears such as in the following example DCBX Parameters Raw Data for CNA Instance 0 QLE8142 Fri May 01 14 27 10 2009 DCBX TLV Type Length Value Data 0D 04 0E 00 00 01 00...

Page 173: ...ee the help menu options rearranged into alphabetical order in Appendix D Exit Codes 14 or 15 Help 2 Exit Codes When you select the Exit Codes option SANsurfer FC CNA HBA CLI shows the entire list of...

Page 174: ...3 Interactive Commands Help Menu Command Line Option h 3 122 SN0054614 00 K Notes...

Page 175: ...nd Summary on page 4 5 Display System Information Command Line Options g z and tp When you enter one of these options general information appears in various formats For example scli g shows the host i...

Page 176: ...ommand Line Option g on page 4 1 as well as the following additional information HBA General information HBA Vital Product Data VPD HBA Parameter Settings Driver Settings Information Group Persistent...

Page 177: ...itional information Interconnect Element switch or adapter Type switch or adapter World wide name Domain ID Management ID IP address Model Symbolic name Serial number MAC address Firmware version Port...

Page 178: ...er model if applicable Adapter serial number if applicable Adapter alias if applicable Port alias if applicable Driver version Firmware version Total number of devices if applicable Host if applicable...

Page 179: ...in XML format see x Output in XML Format 1 on page 4 48 For example scli i all x o output xml g Show system information g Display System Information on page 4 18 i Show adapter information i Display...

Page 180: ...tus Use the a command to either view 1 or change 2 the status of a beacon Table 4 2 Command Variables Variable Definition Format hba instance Adapter numbera a You can use the g command to find adapte...

Page 181: ...toggles the LED s state If the LED is flashing the flashing stops If the LED is not flashing the flashing begins If SANsurfer FC CNA HBA CLI is not in silent mode see s Silent Mode on page 4 45 one o...

Page 182: ...se the cna command to work with converged network adapters QLE81xx and QMI81xx all All adapters of the same type in the system are updated with the new BIOS FCode hba instance Adapter number use g com...

Page 183: ...ommand scli cna hba instance hba wwpn savecfg mpi file To view DCBX Type Length Value TLV data sent and received over the adapter port connection issue the following command scli cna hba instance hba...

Page 184: ...ameters Parameter Name Parameter Alias Parameter Value Description AutoPoll AP 0 1 256 Set to auto polling mode Set to manual polling mode iteration SetRate SR 5 30 Set the polling interval rate secon...

Page 185: ...dapter scli e hba instance hba wwpn view In Solaris SPARC if the system is running with a csh or tsch shell include double quotes around the question mark For example scli e hba In Windows and Linux e...

Page 186: ...00 00 00 00 00 00 00 00 00 00 00 00 00 0 Press Enter to continue To cause the OS to boot from the first target it finds with a LUN select a boot port name of 00 00 00 selectable boot this applies only...

Page 187: ...parameter or menu selection the following message appears The HBA already has that device selected as boot device To use selectable boot the OS boots from the first target the BIOS finds set the targe...

Page 188: ...m file fcoe Display and Configure FCoE Engine Parameters Use the fcoe commands to view and modify the FCoE engine for QLE8042 and Cisco Unified Computing System UCS converged network adapters Display...

Page 189: ...t1 FCoE access port 1 Table 4 4 FCoE Engine Parameters Parameter Name param name Alias param alias Value param value Description PortType AT 0 1 0 Access default 1 Trunk PauseType PT 1 2 1 Standard Pa...

Page 190: ...mands the variables indicate the following fg Show Driver Settings To show the driver settings type scli fg hba instance hba wwpn view Where fs Configure Driver Settings Type the following command to...

Page 191: ...ort use g command to find hba wwpn World wide port name of the adapter param name Name of the parameters param alias Alias of the parameters param value New value of the parameters Table 4 5 Driver Se...

Page 192: ...the IOCTL or sysfs inbox driver hba instance Adapter number use g command to find hba wwpn World wide port name of the adapter param name Name of the parameter see table 4 7 param alias Alias of the p...

Page 193: ...pn target wwpn target portid shows LUN information for a specific target scli l hba no hba wwpn target wwpn target portid lun id shows LUN information for a specific LUN on a specific target ha Set De...

Page 194: ...command scli i all VPD Where To show general or VPD information for a specific adapter type scli I hba instance hba wwpn VPD To show VPD QLA QLE24xx only for all adapter ports in the system type scli...

Page 195: ...the data pattern is either DP param value DataPattern param value hba instance Adapter number use g command to find hba wwpn World wide port name of the adapter ex or exclude World wide port name of t...

Page 196: ...CSPAT for a loopback test For example scli kl hba instance hba wwpn DP CJTPAT Table 4 7 lists all valid data patterns Table 4 7 Data Pattern Values Hexadecimal Binary 00 00000000 55 01010101 5A 010110...

Page 197: ...32 64 128 256 512 1024 2048 4096 8192 16384 32768 or 65535 The default value is 512 bytes TestCount TC The test count specifies the number of loopback tests TC param value TestCount param value For a...

Page 198: ...ype parameter specifies the type of loopback tests that you can select from as shown in Table 4 9 Be sure to select the appropriate adapter connector for testing For internal loopback a loopback conne...

Page 199: ...scli kl hba wwpn DP FF DS 8 TC 500 TI 10 OE 1 NOTE The loopback test is disabled if you are using the drivers from the OS installation and not functional on the QLE8042 adapter NOTE Run an echo test...

Page 200: ...l hba wwpn DS 16 OE 2 An example of a successful loopback test follows Test Configuration Data Pattern Random Data Size Bytes 512 Number of test s 0 65535 N A Test Increment 1 65535 125 On Error Ignor...

Page 201: ...Disparity error Frame length error kr Run Read Write Buffer Test Use the kr command to do read write buffer test To run the loopback test use the kl command see kl Loopback Test on page 4 20 To do a...

Page 202: ...ead Buffer command to read the returned data and do a data comparison hba instance Adapter number use g command to find hba wwpn World wide port name of the adapter ex or exclude World wide port name...

Page 203: ...nd line the current parameter value is used For example the following command sets the data pattern to FFh and uses the current values for the other parameters scli kr hba instance DP FF The following...

Page 204: ...tion DataPattern DP Test pattern in hex formata Customized 00 FF Random pattern CRPATb CJTPATc CSPATd a Valid two character case insensitive hexadecimal patterns b Compliant random data pattern in a v...

Page 205: ...pported Write buffer failed c Compliant jitter tolerance pattern in a FC frame as defined by the ASIC document listed above d Compliant supply noise test sequence in a valid FC frame as defined by the...

Page 206: ...hba wwpn To show the LUN information for a specific device for a specific adapter port type scli l hba instance hba wwpn target port id target wwpn To show the LUN information for a specific LUN on a...

Page 207: ...d automatically until the user aborts the operation When the AutoPoll parameter is in the range of 1 256 the link status is retrieved for the number of cycles specified by this value Sets link status...

Page 208: ...ctive LUN list type scli m hba instance hba wwpn all view In Solaris SPARC include double quotes around the question mark if the system is running with a csh or tsch shell For example scli m HBA SANsu...

Page 209: ...ecific adapter scli m hba instance hba wwpn select all To disable deselect all LUNs of all targets on a specific adapter scli m hba instance hba wwpn deselect all n Set Selected HBA Parameter To set a...

Page 210: ...Enable 0 Disable Enable FC tape EnableFCTape EF 1 Enable 0 Disable Enable hard loop ID EnableHardLoopID HL 1 Enable 0 Disable Enable LIP full login EnableLIPFullLogin FL 1 Enable 0 Disable Enable LIP...

Page 211: ...c EnableBIOS option not available on 4Gb adapter d EnableExtendedLogging option not available on PPC64 or SPARC e Operation mode QLA QLE23xx QLA QLE24xx and 8Gb adapters 0 interrupt for every I O comp...

Page 212: ...stent binding information for a specific adapter port type scli p hba instance hba wwpn view To show persistent binding information for all adapters type scli p all view Where Windows syslog log in th...

Page 213: ...scli p hba instance hba wwpn target wwnn target wwpn target port id target id Where To bind multiple targets with a single command repeat the following group target wwnn target wwpn target port id tar...

Page 214: ...he specified adapter type scli pa hba instance hba wwpn alias Where To delete a port alias for the specified adapter port type scli pa hba instance hba wwpn delete To view a port alias for the specifi...

Page 215: ...type scli pl hba instance hba wwpn del target id lun id lun name Where NOTE The pl option is available only on Linux RHEL 5 x systems this option is not supported for SLES 11 CAUTION Do not delete a...

Page 216: ...enter the following command scli q hba instance hba wwpn all targets t speed Where NOTE The q option is supported only on 4GB adapters hba instance Adapter number use g command to find hba wwpn World...

Page 217: ...tings for a specific virtual port on a physical adapter port enter the following command scli qos hba instance hba wwpn info vp vport wwpn To change QoS settings for specified virtual ports enter the...

Page 218: ...eed to assign to the virtual port speed Value of bandwidth speed bwper Bandwidth percentage to assign to the virtual port percent Value of bandwidth percent lock Specify the lock value lock value Lock...

Page 219: ...pecific adapter type scli t hba instance hba wwpn To show specific target information for a specific target on an adapter type scli t hba instance hba wwpn target wwpn target port id Where To show the...

Page 220: ...to show the topology configuration of the host scli tp topology Under Linux this feature is disabled if you are using the IOCTL or sysfs inbox driver Host Topology Command Line Option tp on page 4 3...

Page 221: ...e following information SANsurfer FC CNA HBA CLI v1 x x Build x Copyright 2003 2009 QLogic Corp All rights reserved Command Line QLogic FC Host Bus Adapters Build Type Release Build Date xx xx xxxx xx...

Page 222: ...instance hba wwpn delete vport wwpn x Output in XML Format 1 You can use this option with all non interactive mode options that have a corresponding interactive mode option see Table 4 1 This option m...

Page 223: ...ats are described in Appendix B This option is usually combined with the o option see o Output to a File on page 4 37 to create a text file with XML output so that it can be parsed by an XML compliant...

Page 224: ...4 Non Interactive Commands Command Summary 4 50 SN0054614 00 K Notes...

Page 225: ...Tag When SANsurfer FC CNA HBA CLI is in XML mode all outputs are within the main tag QLogic QLogic Utility Header The following header information is shown after the main tag AppName SANsurfer Command...

Page 226: ...the execution of the command line parameters is successful and the system must be restarted for the change to take effect the following message is shown Reboot 1 Reboot When the execution of the comm...

Page 227: ...1 Link Statistics Command Line Option ls on page A 14 HBA Statistics Command Line Option gs on page A 14 HBA Alias Command Line Option ha on page A 15 HBA Port Alias Command Line Option pa on page A 1...

Page 228: ...CLI AppName AppVersion vn nn nn Build nn AppVersion HBA HBA Port value WWNN value WWPN value Param ConnectionOption value DataRate value FrameSize value HardLoopID value LoopResetDelay value EnableHo...

Page 229: ...neralInfo Port value Model value HBAID value HBAAlias value HBAPort value PortAlias value WWNN value WWPN value PortID value SerialNumber value DriverVersion value BIOSVersion value FirmwareVersion va...

Page 230: ...ount value PCIBus value PCIDevice value ActualConnectionMode value ActualDataRate value PortType value Status value HBA Status 0 Status Reboot 0 Reboot QLogic Here is the VPD information xml version 1...

Page 231: ...Target WWPN WWPN Info Path value ID value Vendor value ProductID value Revision value SerialNumber value DeviceID value PortID value LunCount value Type value DeviceStatus value Target HBA Status 0 St...

Page 232: ...t 1 for the adapter target persistent binding information is as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion vn nn nn Build nn AppVersion HBA...

Page 233: ...rmation is as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion vn nn nn Build nn AppVersion HBA HBA Port value WWNN value WWPN value BootDevice Ta...

Page 234: ...ue WWPN value Target WWNN Target WWNN WWNN WWPN Target WWPN WWPN Loop ID value DataMiscompare value LinkFailure value LossOfSync value LossOfSignal value InvalidCRC value Result value Target HBA Statu...

Page 235: ...as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion vn nn nn Build nn AppVersion Table A 1 Options Shown by z Non interactive Option Description...

Page 236: ...s value WWNN value WWPN value PortID value SerialNumber value DriverVersion value BIOSVersion value FirmwareVersion value TargetCount value PCIBus value PCIDevice value ActualConnectionMode value Actu...

Page 237: ...ue PortID value LunCount value Type value DeviceStatus value LUN ID value WWULN value Vendor value Product value Revision value Size value Type value EnabledLUN ID value LUNWWNN value LUNWWPN value Ta...

Page 238: ...ic HBA Statistics Command Line Option gs The XML Format 1 for the adapter statistics option is as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion...

Page 239: ...ANsurfer FC CNA HBA CLI AppName AppVersion vn nn nn Build nn AppVersion HBA HBA Port value WWNN value WWPN value HBAAlias Alias Name value HBAAlias HBA Status 0 Status Reboot 0 Reboot QLogic HBA Port...

Page 240: ...ion SerialNumber value SerialNumber MediaInformation Diagnostics Temperature MeasuredTemperature C MeasuredTemperature Value value Value Status value Status HighAlarm value HighAlarm HighWarning value...

Page 241: ...rmat 1 for adapter transceiver details detailed information is as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion vn nn nn Build nn AppVersion HB...

Page 242: ...BR Min value BR Min VendorSN value VendorSN DateCode value DateCode DiagMonitoringType AddressChangeRequired value AddressChangeRequired PowerMeasurement value PowerMeasurement ExternallyCalibrated v...

Page 243: ...e RXPowerHighWarning RXPowerLowWarning value RXPowerLowWarning Rx_PWR 4 value Rx_PWR 4 Rx_PWR 3 value Rx_PWR 3 Rx_PWR 2 value Rx_PWR 2 Rx_PWR 1 value Rx_PWR 1 Rx_PWR 0 value Rx_PWR 0 Tx_I_Slope value...

Page 244: ...rning value TXBiasLowWarning TXBiasHighWarning value TXBiasHighWarning VccLowWarning value VccLowWarning VccHighWarning value VccHighWarning TempLowWarning value TempLowWarning TempHighWarning value T...

Page 245: ...mainID value ManagementID value IPAddress value Model value SymbolicName value SerialNumber value MACAddress value FirmwareVersion value PortCount value BeaconStatus value PhysicalPortInformation Phys...

Page 246: ...TXPortType value ModuleType value AttachedPort Type Target Target NodeName value PortName value VendorId value ProductId value ProductRevision value ProductSerialNumber value AttachedPort AttachedPor...

Page 247: ...ncoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion 1 7 1 23 AppVersion HBA HBA Port 3 WWNN 20 00 00 E0 8B 80 5F 0F WWPN 21 00 00 E0 8B 80 5F 0F Menlo Parameters PortSelectio...

Page 248: ...0 02 03 120 Host fibre channel port 0 physical link up Entry No 1 Info 000 00 02 03 120 Host fibre channel port 1 physical link up Entry No 2 Info No Data Entry No 3 Info No Data Entry No 4 Info No Da...

Page 249: ...CLI AppName AppVersion 1 7 1 23 AppVersion HBA HBA Port 3 WWNN 20 00 00 E0 8B 80 5F 0F WWPN 21 00 00 E0 8B 80 5F 0F xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName...

Page 250: ...y No 19 Info No Data FCoELogs HBA Status 0 Status Reboot 0 Reboot QLogic HBA QLogic Display FCoE Network Interface Statistics The XML Format 1 for FCoE network interface statistics output is as follow...

Page 251: ...0 NumberofTransmittedPacketsLessThanOrEqual1518bytes NumberofTransmittedPacketsLessThanOrEqual2047bytes 0 NumberofTransmittedPacketsLessThanOrEqual2047bytes NumberofTransmittedPacketsLessThanOrEqual4...

Page 252: ...withVLANtag NumberofTransmitted_802_3x_PauseControlPackets 0 NumberofTransmitted_802_3x_PauseControlPackets NumberofTransmittedPer PriorityPausePackets 0 NumberofTransmittedPer PriorityPausePackets Nu...

Page 253: ...ual4095bytes 0 NumberofReceivedPacketsLessThanOrEqual4095bytes NumberofReceivedPacketsLessThanOrEqual8191bytes 0 NumberofReceivedPacketsLessThanOrEqual8191bytes NumberofReceivedPacketsLessThanOrEqual9...

Page 254: ...ketsDiscardedbytheMAC 0 NumberofReceivedPacketsDiscardedbytheMAC NumberofReceivedUndersizedPacketsWithGoodCRC 0 NumberofReceivedUndersizedPacketsWithGoodCRC NumberofReceivedUndersizedPacketsWithBadCRC...

Page 255: ...A XML Format 1 XML Format 1 Tags for Each Option SN0054614 00 K A 31 NumberofReceivedPer PriorityPausePackets NSLPortStatistics HBA Status 0 Status Reboot 0 Reboot QLogic...

Page 256: ...A XML Format 1 XML Format 1 Tags for Each Option A 32 SN0054614 00 K Notes...

Page 257: ...consists of the following parts Main Tag on page B 1 Utility Header on page B 2 Status Message on page B 2 Reboot Message on page B 2 Error Message on page B 2 Main Tag When SANsurfer FC CNA HBA CLI...

Page 258: ...ommand line parameters fails the following status is shown followed by an error message that provides additional details Status 1 Status Reboot Message When the execution of the command line parameter...

Page 259: ...on page B 11 Diagnostics Results Read Write Buffer Test Command Line Option kr on page B 12 View Driver Settings Command Line Option fg on page B 12 Display All Information for One or All Adapters Co...

Page 260: ...on SDMAPIVersion n nn nn nn SDMAPIVersion HBA Instance value HBAModel value HBAPort value WWNN value WWPN value NumOfHBA n NumOfHBA Host Status n Status ErrorMsg message ErrorMsg Reboot n Reboot QLogi...

Page 261: ...adapter Each parameter is listed on a separate line for clarity however multiple parameters can be on the same line For multiple adapters repeat the preceding sequence with the ID number ID Number va...

Page 262: ...Format 2 for 4G adapters is as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion vn n n Build n AppVersion AppXmlVersion 2 0 AppXmlVersion HBA Gen...

Page 263: ...tNumber value SerialNumber value MiscInformation value ManufacturingID value EFIDriverVersion value FirmwareVersion value BIOSVersion value FCodeVersion value VPD HBA Status 0 Status Reboot 0 Reboot Q...

Page 264: ...et The HBA HBA sequence repeats for each adapter Display LUN List Command Line Option l The command format is scli l hba instance hba wwpn x2 The XML Format 2 for the adapter LUN list information is a...

Page 265: ...CNA HBA CLI AppName AppVersion vn n nn Build nn AppVersion AppXmlVersion n nn AppXmlVersion HBA HBA Instance value HBAModel value HBAPort value WWNN value WWPN value TargetBinding TargetWWNN value Ta...

Page 266: ...mat for a single adapter is e hba instance hba wwpn view x2 The XML Format 2 for the boot device information is as follows xml version value encoding value QLogic AppName SANsurfer FC CNA HBA CLI AppN...

Page 267: ...AppVersion vn n nn Build nn AppVersion AppXmlVersion n nn AppXmlVersion HBA HBA Instance value HBAModel value HBAPort value WWNN value WWPN value Loop ID value CRCError value DisparityError value Fram...

Page 268: ...nn AppXmlVersion HBA HBA Instance value HBAModel value HBAPort value WWNN value WWPN value Target WWNN Target WWNN WWNN WWPN Target WWPN WWPN Loop ID value DataMiscompare value LinkFailure value LossO...

Page 269: ...l the options in Table B 1 and each option is shown in its standard output format If each option shows its own XML2 output the resulting display would have multiple duplicate tags Table B 1 Options Sh...

Page 270: ...Version HBA Instance value HBAModel value HBAPort value WWNN value WWPN value NumOfHBA Number of HBA s detected NumOfHBA Host HBA HBA Instance value HBAModel value HBAPort value WWNN value WWPN value...

Page 271: ...tDelayTimer value ExecutionThrottle value LoginRetryCount value EnableLipReset value PortDownRetryCount value EnableLipFulllogin value LinkDownTimeout value EnableTargetReset value LUNsPerTarget value...

Page 272: ...param name param alias param value x2 The XML Format 2 for the link statistics option is as follows xml version value encoding value QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion vn n nn...

Page 273: ...Line Option gs The command format is scli gs hba instance hba wwpn param name param alias param value x2 The XML Format 2 for the adapter statistics option is as follows xml version value encoding va...

Page 274: ...BAModel value HBAPort value WWNN value WWPN value HBAAlias AliasName value HBAAlias HBA Status n Status Reboot n Reboot QLogic HBA Port Alias Command Line Option pa The command format is scli pa hba i...

Page 275: ...mber value SerialNumber MediaInformation Diagnostics Temperature MeasuredTemperature C MeasuredTemperature Value value Value Status value Status HighAlarm value HighAlarm HighWarning value HighWarning...

Page 276: ...atus Reboot 0 Reboot QLogic HBA Transceiver Details Command Line Option dm The XML Format 2 for adapter transceiver details general information is as follows scli dm hba instance hba wwpn all general...

Page 277: ...owAlarm value LowAlarm Voltage TxBias MeasuredTxBiasUnit mA MeasuredTxBiasUnit Value value Value Status value Status HighAlarm value HighAlarm HighWarning value HighWarning LowWarning value LowWarning...

Page 278: ...ier Ext Identifier value Ext Identifier Connector value Connector TransceiverData Compliance value Compliance FCLinkLength value FCLinkLength FCTransmitterTech value FCTransmitterTech FCTransmissionMe...

Page 279: ...onitoring SoftTXDisableCtrlAndMonitoring value SoftTXDisableCtrlAndMonitoring Alarm WarningFlags value Alarm WarningFlags EnhancedOptions SFF 8472 Compliance value SFF 8472 Compliance CC_EXT 0x7d CC_E...

Page 280: ...B TX_Power_LSB value TX_Power_LSB RX_Power_MSB value RX_Power_MSB RX_Power_LSB value RX_Power_LSB Reserved_MSB value Reserved_MSB Reserved_LSB value Reserved_LSB Reserved_MSB value Reserved_MSB Reserv...

Page 281: ...lue ReservedWarning RXPowerLowWarning value RXPowerLowWarning RXPowerLowWarning value RXPowerLowWarning VendorSpecific value VendorSpecific Address_A2 HBA Status n Status ErrorMsg message ErrorMsg Reb...

Page 282: ...erVersion value FirmwareVersion value Host value AttachPort PhysicalPort PhysicalPortInformation InterconnectElements InterconnectElementType HBA HBA WWNN value WWPN value VendorID value Model value S...

Page 283: ...Logic Display FCoE Parameters The XML Format 2 for FCoE parameter output is as follows xml version 1 0 encoding ISO 8859 1 QLogic AppName SANsurfer FC CNA HBA CLI AppName AppVersion 1 7 1 23 AppVersio...

Page 284: ...e AppVersion 1 7 1 23 AppVersion HBA FCoELogs LogID ID 8 LogName Link Events Entry No 0 Info 000 00 01 58 480 Host fibre channel port 0 physical link up Entry No 1 Info 000 00 02 03 120 Host fibre cha...

Page 285: ...Logic AppName SANsurfer FC CNA HBA CLI AppName AppVersion 1 7 1 23 AppVersion HBA HBA Instance 3 HBAModel QLE8402 HBAPort 1 WWNN 20 00 00 E0 8B 80 5F 0F WWPN 21 00 00 E0 8B 80 5F 0F xml version 1 0 en...

Page 286: ...y No 17 Info No Data Entry No 18 Info No Data Entry No 19 Info No Data FCoELogs HBA Status 0 Status Reboot 0 Reboot QLogic HBA QLogic Display FCoE Network Interface Statistics The XML Format 2 for FCo...

Page 287: ...PacketsLessThanOrEqual1024bytes NumberofTransmittedPacketsLessThanOrEqual1518bytes 0 NumberofTransmittedPacketsLessThanOrEqual1518bytes NumberofTransmittedPacketsLessThanOrEqual2047bytes 0 NumberofTra...

Page 288: ...ittedBroadcastPackets NumberofTransmittedPacketswithVLANtag 0 NumberofTransmittedPacketswithVLANtag NumberofTransmitted_802_3x_PauseControlPackets 0 NumberofTransmitted_802_3x_PauseControlPackets Numb...

Page 289: ...mberofReceivedPacketsLessThanOrEqual2047bytes NumberofReceivedPacketsLessThanOrEqual4095bytes 0 NumberofReceivedPacketsLessThanOrEqual4095bytes NumberofReceivedPacketsLessThanOrEqual8191bytes 0 Number...

Page 290: ...eivedOversizedPackets 0 NumberofReceivedOversizedPackets NumberofReceivedPacketsDiscardedbytheMAC 0 NumberofReceivedPacketsDiscardedbytheMAC NumberofReceivedUndersizedPacketsWithGoodCRC 0 NumberofRece...

Page 291: ...ags for Each Option SN0054614 00 K B 35 NumberofReceived_802_3x_PauseControlPackets NumberofReceivedPer PriorityPausePackets 0 NumberofReceivedPer PriorityPausePackets NSLPortStatistics HBA Status 0 S...

Page 292: ...B XML Format 2 XML Format 2 Tags for Each Option B 36 SN0054614 00 K Notes...

Page 293: ...NOTE Error return codes are continually being updated Although Table C 1 was accurate at the time this document was written you should check for the latest return codes in the file Fcscli exicodes txt...

Page 294: ...used 18 Reserved Not used 19 ERROR_FLASH_UPDATE_UNSUPPORTED Flash update is not supported with this adapter 20 ERROR_FLASH_OPTION_DISABLED_HBA Flash update is disabled with this adapter 21 ERROR_FLAS...

Page 295: ...VALID_VPD Flash contains invalid VPD 40 ERROR_DIAGNOSTICS_PARAM_ERROR Diagnostics test returns invalid parameters 41 ERROR_DIAGNOSTICS_LOOP_DOWN Unable to run diagnostics because the loop is down 42 E...

Page 296: ..._UNSUPPORTED_HBA Specified adapter parameters is not cur rently supported 62 ERROR_PARAM_UNSUPPORTED_DRIVER Unable to update adapter parameters the driver is unsupported 63 ERROR_RESTORE_NVRAM_DEFAULT...

Page 297: ...84 ERROR_MISSING_NVRAM_TEMPLATE_ FILE Unable to find the NVRAM template for the adapter 85 ERROR_INVALID_NVRAM_PROG_OPTION Specified key value to program NVRAM are invalid 86 ERROR_SPECIFIC_OEM_TEMPLA...

Page 298: ...settings 103 ERROR_UNSUPPORTED_DRIVER_PARAM Unsupported driver parameter 104 Reserved Not used 105 Reserved Not used 106 Reserved Not used 107 Reserved Not used 108 Reserved Not used 109 Reserved Not...

Page 299: ...led because of current driver 125 ERROR_UPDATE_LUN_DATA_PERSIST_ BINDING Failed to update LUN data during persistent binding configuration 126 ERROR_FAILOVER_DRIVER_LOADED Feature is not supported wit...

Page 300: ...d to create temporary directory 149 ERROR_OPEN_ZIP_FILE Failed to open zip file 150 ERROR_CLOSE_ZIP_FILE Failed to close zip file 151 ERROR_READ_ZIP_FILE Failed to read zip file 152 ERROR_EXTRACT_ZIP_...

Page 301: ...Reserved Not used 171 IBM Reserved Blocked 172 IBM Reserved Blocked 173 IBM Reserved Blocked 174 IBM Reserved Blocked 175 IBM Reserved Blocked 176 IBM Reserved Blocked 177 IBM Reserved Blocked 178 IBM...

Page 302: ...used 202 Reserved Not used 203 Reserved Not used 204 Reserved Not used 205 Reserved Not used 206 Reserved Not used 207 Reserved Not used 208 Reserved Not used 209 Reserved Not used 210 ERROR_MISSING_...

Page 303: ...sed 229 Reserved Not used 230 ERROR_GET_TARGET_IIDMA_SETTINGS Failed to query current intelligent inter leaved direct memory access setting 231 ERROR_SAVE_TARGET_IIDMA_SETTINGS Failed to set intellige...

Page 304: ...248 Reserved Not used 249 Reserved Not used 250 ERROR_GET_HBA_ALIAS Failed to retrieve adapter alias of the adapter 251 ERROR_UPDATE_HBA_ALIAS Failed to update adapter alias of the adapter 252 ERROR_G...

Page 305: ...a virtual port of the adapter 281 ERROR_DELETE_VIRTUAL_PORT Failed to delete a virtual port of the adapter 282 ERROR_INVALID_VIRTUAL_PORT_WWN Virtual port WWPN is invalid 283 ERROR_VIRTUAL_PORT_NOT_FO...

Page 306: ...rmware version 302 ERROR_UPDATE_MENLO_FW Failed to update FCoE firmware 303 ERROR_MANAGE_MENLO_INFO Failed to execute FCoE operation com mands 304 ERROR_GET_MENLO_CONFIG Failed to retrieve FCoE parame...

Page 307: ...2 ERROR_INVALID_BYTES Invalid bytes input 323 ERROR_INVALID_DIAG_ADDRESS Invalid FCoE memory buffer address 324 ERROR_INVALID_DIAG_SIZE Invalid FCoE memory buffer size 325 ERROR_INVALID_DIAG_INPUTS In...

Page 308: ...d udev persistent device name 345 ERROR_OS_UNSUPPORTED_ PERSISTENT_NAME Udev persistent device name feature is not supported with current OS kernel 346 ERROR_UNSUPPORTED_LUN_TYPE Selected device is no...

Page 309: ...ABLE_STATE Failed to enable disable QoS enable set ting state 371 ERROR_UPDATE_VPORT_LOCK_STATE Failed to modify QoS lock setting state 372 ERROR_UPDATE_PPORT_ENABLE_STATE Failed to modify QoS enable...

Page 310: ...ecksum 433 ERROR_SFP_UPDATE_FAILED Failed to update Electronic Dispersion Compensation EDC firmware 434 ERROR_SFP_UPDATE_UNSUPPORTED Selected option is unsupported 435 ERROR_SFP_UPDATE_NON_ZERO_ COUNT...

Page 311: ...BOOT_CODE Failed to update FC boot code 459 ERROR_UPDATE_FC_FIRMWARE Failed to update FC firmware 460 ERROR_MPI_CFG_UPDATE_FAILURE Failed to update MPI configuration 461 ERROR_MPI_CFG_SAVE_FAILURE Fai...

Page 312: ...used 474 Reserved Not used 475 Reserved Not used 476 Reserved Not used 477 Reserved Not used 478 Reserved Not used 479 Reserved Not used 480 ERROR_GET_DCBX_PARAMETERS Failed to get DCBX TLV Table C 1...

Page 313: ...umber of an adapter port hba wwpn World wide port name of an adapter port xx xx xx xx xx xx xx xx or xxxxxxxxxxxxxx enable value Enable value 1 for enable or 0 for disable file name Firmware preload t...

Page 314: ...ED state on an adapter port b all hba instance hba wwpn rg fw boot all file name Updates the adapter boot code from a file where rg Specifies Option ROM region update mode all Updates the flash from a...

Page 315: ...nds e hba instance hba wwpn view Shows the current boot device information on an adapter port e hba instance hba wwpn view Shows the current boot device information on an adapter port e hba instance h...

Page 316: ...other options fcoe hba instance hba wwpn info Shows current FCoE firmware version fcoe hba instance hba wwpn getparam portx Shows FCoE parameters of specified port fcoe hba instance hba wwpn setparam...

Page 317: ...VPD information of an adapter port i all vpd Views the general or VPD information of all adapters kl hba instance hba wwpn param name param alias param value Runs a diagnostics loopback test on an ad...

Page 318: ...ices attached to an adapter port Disable m hba instance hba wwpn unselect all Configures all LUNs of all devices attached to an adapter port Disable m hba instance hba wwpn target wwnn target wwpn lun...

Page 319: ...n adapter port pa hba instance hba wwpn view Shows the current alias of an adapter port pl hba instance hba wwpn info target id lun id Shows persistent device names for a spe cific LUN or all LUNs Lin...

Page 320: ...e Updates the adapter parameters of an adapter port or all adapters from a file s Suppresses the output This option can be combined with other options However this option must be at the beginning or a...

Page 321: ...port vp hba instance hba wwpn list all Lists all virtual ports on a physical adapter port x Writes the output in XML format 1 Option x can be used to generate an old style format that is compatible w...

Page 322: ...D Help Commands D 10 SN0054614 00 K Notes...

Page 323: ...loop_physical address See AL_PA basic input output system See BIOS BIOS Basic input output system typically in Flash PROM The program or utility that serves as an interface between the hardware and t...

Page 324: ...ies Enhanced Ethernet and Fibre Channel over Ethernet FCoE converged network adapter See CNA CoS Class of service CoS is a 3 bit field within a layer two Ethernet frame header when using IEEE 802 1Q I...

Page 325: ...aces between the file system and a physical data storage device or network media E_Port Expansion port A port in an FC switch that connects to another FC switch or bridge device by an inter switch lin...

Page 326: ...bre Channel over Ethernet See FCoE FL_Port Fabric loop port In FC the fabric switch is capable of FC arbitrated loop operations and is connected to one or more NL_Ports by an FC arbitrated loop An FL_...

Page 327: ...ation process The initializa tion process in an arbitrated loop that occurs when the loop is powered up or a new device is added One function of a LIP is to assign addresses All data transmis sion on...

Page 328: ...egisters Optional features in MSI 64 bit addressing and interrupt masking are mandatory with MSI X N_Port Node port A port that connects by a point to point link to either a single N_Port or a single...

Page 329: ...s guide open network computing See ONC ONC Open network computing A remote proce dure call developed by Sun Microsystems path A path to a device is a combination of a adapter port instance and a targe...

Page 330: ...ntroller bus SerDes A Serializer Deserializer SerDes pronounced sir dees is a pair of functional blocks commonly used in high speed communications These blocks convert data between serial data and par...

Page 331: ...vides a user space Appli cation Programming Interface API to access information about current system devices udev relies on device information available through sysfs virtual logical area network See...

Page 332: ...SANsurfer FC CNA HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Glossary 10 SN0054614 00 K Notes...

Page 333: ...FCoE engine 3 33 adapter port BIOS enabling 3 26 3 30 definition of Glossary 1 diagnostics 3 77 iiDMA settings 3 50 statistics options 3 91 adapter port alias creating modifying deleting 3 22 definiti...

Page 334: ...us toggling 4 6 status viewing 4 6 target locating 3 75 target starting and stopping 4 46 Beacon Menu 3 75 bind by port ID parameter 4 17 by WWPN parameter 4 17 targets 3 57 binding information viewin...

Page 335: ...4 47 x 3 10 4 48 x2 3 10 4 48 z 3 10 3 19 4 2 4 4 4 49 A 11 B 13 config table MPI saving 3 71 updating 3 71 configuration saving 3 62 configuring adapter statistics 3 90 boot device 3 61 4 4 driver se...

Page 336: ...94 defining port alias 4 40 definitions of terms Glossary 1 delay timer interrupt 3 26 3 30 delay loop reset 3 26 deleting virtual port 3 99 device configuring boot 3 61 definition of Glossary 3 drive...

Page 337: ...30 FC tape support 3 26 Fibre Channel tape support 3 30 LIP full login 3 27 3 31 LIP reset 3 26 3 31 LUNs 4 33 receive out of order frame 3 27 target reset 3 27 3 31 virtual port 3 103 3 106 3 107 end...

Page 338: ...nel over Ethernet See FCoE Fibre Channel definition of Glossary 4 file 3 10 txt 3 10 xml 3 10 text 3 10 XML 3 10 firmware preload table saving 3 70 preload table updating 3 69 updating on ASIC chip 3...

Page 339: ...second IOPS definition of Glossary 5 installation downloading package 1 7 Linux 1 14 Macintosh 1 18 package downloading 1 7 prerequisites of 1 1 Solaris 1 15 Solaris SPARC 8 9 10 1 15 Solaris x86 9 1...

Page 340: ...driver 3 5 uninstalling from 1 22 LIP definition of Glossary 5 full login enabling 3 27 3 31 4 36 reset enabling 3 26 4 36 listing error codes 4 13 target LUN 3 36 virtual ports 3 99 load balancing d...

Page 341: ...ry 6 message passing interface See MPI message signaled interrupts extension See MSI X messages output to XML Format 1 4 48 Microsoft System Center Virtual Machine CLI 2007 3 97 Microsoft s Windows Vi...

Page 342: ...adapter configuring 3 26 adapter viewing 3 24 3 26 4 8 data rate 3 26 parameters continued defaults restoring 3 32 diagnostic 4 30 FCoE engine A 23 B 27 FCoE configuring 3 33 FCoE viewing 3 33 frame...

Page 343: ...101 4 43 QoS Bandwidth Menu 3 104 QoS Menu 3 101 QoS Priority Menu 3 103 quality of service See QoS R r 3 65 3 66 4 44 rate data 3 29 read write buffer test 3 83 results A 10 B 12 running 3 83 4 27 4...

Page 344: ...equirement for 1 1 silent mode 4 5 4 45 size frame 3 29 SLA service level agreement 3 101 small computer system interface definition of Glossary 8 small form factor pluggable See SFP software requirem...

Page 345: ...4xx adapters ISP2422 3 67 QLA24xx QLE24xx adapters ISP2432 3 67 QLE256x adapters ISP2422 3 67 QLE256x adapters ISP2432 3 67 ten bit internal loopback test 3 82 terminology used in guide 2 9 terms defi...

Page 346: ...ings 4 4 beacon status 4 6 boot device 4 11 driver settings 4 4 link status 3 96 LUN list 4 5 4 33 viewing continued parameter settings 4 8 system information 4 5 target link speed 4 42 target list 4...

Page 347: ...lossary 9 notation for 2 4 WWPN bind by WWPN parameter 4 17 definition of Glossary 9 notation for 2 4 X x 3 10 4 5 4 48 x1 A 1 x2 3 10 4 48 XML file saving as 3 10 Format 1 3 10 4 48 A 1 Format 2 3 10...

Page 348: ...stered trademarks of Novell Inc IBM and PowerPC are registered trademarks of International Business Machines Corporation Red Hat is a registered trademark of Red Hat Inc Solaris is a registered tradem...

Reviews: