INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G10.2 / G10.c – Q CELLS

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G10.2 / G10.c – Q CELLS

With solar modules from Hanwha Q CELLS America Inc.(hereafter 
referred to as "Q CELLS") you can directly transform the sun’s 
limitless energy into environmentally-friendly solar electricity. 
In order to ensure the maximum performance of your Q CELLS 
solar modules, please read the following instructions completely 
and carefully and observe all guidelines. Non-compliance may 
result in damage and / or physical injury.

This installation manual provides instructions for the safe installation 
and operation of crystalline solar modules.

 

Ä

Please read these instructions carefully before proceeding with 
your installation.

 

Ä

Please retain these instructions for the life of the solar modules.

 

Ä

Please ensure that this installation manual is available to the 
operator at all times.

 

Ä

This installation manual should be given to all subsequent owners 
or users of the solar modules.

 

Ä

All supplements received from the manufacturer should be 
included.

 

Ä

Please observe all other applicable documents.

 

Ä

If your questions are not satisfactorily answered in the manual, 
please contact your system supplier.

Additional information can be found on our website at 
www.q-cells.us.

Intended Use

This Manual is valid in North America for Q CELLS solar modules. 
These instructions contain information regarding the safe handling 
and use of quality crystalline solar modules from Q CELLS and their 
installation, mounting, wiring, maintenance.

Symbols and Labels

The following symbols and labels are used throughout the installation 
manualfor ease of use.

SYMBOL

DESCRIPTION

 

Ä

 

Procedure with one or more steps.

• 

 

Lists of items.

Ensure that when carrying out a procedure, you 
check the results of said procedure.

Prohibited.

Beware of possible danger or damage. 
Categories:

• 

Danger: Risk of fatal injury

• 

Attention: Risk of serious injury or damage 
to property

• 

Note: Risk of damage to product

Units

Where both Imperial and U.S. units (for example inches) are shown, 
metric units are definitive. References to “Data Sheet” or “Module 
Data Sheet” refer to the Module Data Sheet applicable to the 
module being used.

Safety Regulations

The installer and solar module operator are responsible for com-
pliance with all applicable statutory requirements and regulations.

 

Ä

The following regulations and standards must be upheld at all 
times during the installation, operation, and maintenance of 
the solar modules:

• 

Installation and Operation Manual.

• 

Other applicable documents (such as country-specific regu-
lations for pressure equipment, operational safety, hazardous 
goods, and environmental protection).

• 

Regulations and requirements specific to the system.

• 

Applicable country-specific laws, regulations, and provisions 
governing the planning, installation, and operation of solar 
power systems and work on roofs.

• 

Any valid international, national and regional regulations gov-
erning work with direct current, especially those applicable 
to the installation of electrical devices and systems, and reg-
ulations issued by the respective energy provider governing 
the parallel operation of solar power systems.

• 

Accident-prevention regulations.

Certified Personnel

Both, the operator and installer are responsible for ensuring that the 
installation, maintenance, connection to the grid, and dismantling 
are carried out by trained and qualified electricians and engineers 
with approved training certificates (issued by a state or federal 
organization) for the respective specialist trade. Electrical work 
may only be performed by an officially certified tradesperson in 
accordance with the applicable safety standards, accident pre-
vention regulations, and the regulations of the local energy provider. 

1  INTRODUCTION

DOCUMENT REVISION 02
This installation manual is valid for North America as of January 1st 2022 for Q.PEAK DUO XL-G10.2 and Q.PEAK DUO XL-G10.c solar modules, and replaces all earlier versions.

This manual is subject to change. The data sheets and customer information valid at the point in time when the relevant module was manufactured apply to the installation, mounting, and 
maintenance procedures for the respective solar modules, as far as no updated document is provided.

TABLE OF CONTENTS

1 INTRODUCTION 

3

2 PLANNING 

5

2.1  TECHNICAL SPECIFICATIONS 

5

2.2 REQUIREMENTS 

6

2.3  MOUNTING OPTIONS 

7

2.4  ELECTRICAL LAYOUT 

11

3 INSTALLATION 

12

3.1  SAFETY AND TRANSPORT 

12

3.2  PREPARATION OF INSTALLATION 

14

3.3  MODULE INSTALLATION 

15

ELECTRICAL CONNECTION 

16

4.1 SAFETY 

16

4.2  ELECTRICAL INSTALLATION SAFETY 

17

4.3  CONNECTION OF MODULES 

18

4.4  AFTER INSTALLATION 

19

5 GROUNDING 

20

FAULTS AND DEFECTS 

21

7 DISPOSAL 

21

MAINTENANCE AND CLEANING 

22

Summary of Contents for Q.PEAK DUO XL-G10.c

Page 1: ...Valid for North America INSTALLATION AND OPERATION MANUAL Q PEAK DUO XL G10 2 G10 c solar module series...

Page 2: ...are responsible for com pliance with all applicable statutory requirements and regulations The following regulations and standards must be upheld at all times during the installation operation and mai...

Page 3: ...ble documents This installation manual is only valid in combination with the following technical information DOCUMENT TYPE Product data sheet Packaging and transport information MISUSE OR INCORRECT US...

Page 4: ...tress free expansion and contraction due to tem perature fluctuations Ensurethatnoadditionalforcesareappliedthroughthemounting system into the module except for the wind and snow loads Additional forc...

Page 5: ...YSTEM INSTALLATION ON MOUNTING POINTS INSTALLATION WITH INSERTION PROFILES NOT PERMITTED TRACKER INSTALLATION ON MOUNTING POINTS TB1a 35 8 908 TB2a 35 8 908 35 8 28 1 17 9 908 713 454 TB1b 28 1 713 TB...

Page 6: ...the module TC1 Ensure minimum support depth of 12mm on the backside and 10mm on the front side of the module FB1 FB2 TB1a TB2a TB1b TB2b mFB2 Use M8 corrosion proof screws and washers diameter 15 8mm...

Page 7: ...ng factor of 125 percent 80 percent derating which might be applicable Please follow the valid national guidelines for the installation of electrical systems refer to section 690 8 of the NEC for an a...

Page 8: ...out the installation alone Only install undamaged modules and components Do not modify the module e g do not drill any additional holes 3 INSTALLATION 3 2 PREPARATION OF INSTALLATION confirmation let...

Page 9: ...Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the time intervals specified by the inverter manufacturer after switching off the inverter Make sure th...

Page 10: ...ick click DANGER Risk of fatal injury due to electric shock Ensure that all electrical components are in a proper dry and safe condition SOLAR 4 ELECTRICAL CONNECTION 4 3 CONNECTION OF MODULES DANGER...

Page 11: ...and backing nut Care should be taken to avoid the use of grounding hardware of dissimilar metals which may lead to corrosion Option B Integrated grounding methods The Q CELLS modules can be bonded wi...

Page 12: ...ing to the state of the art and taking into account all relevant safety issues and general product properties e g but not restricted to electrical safety mechanical stability load limits depending on...

Page 13: ...ithout notice Q CELLS Installation manual solar modules Q PEAK DUO XL G10 2_G10 c_2022 01_Rev02_NA 24 INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q PEAK DUO XL G10 2 G10 c Q CELLS Free the substru...

Reviews: