background image

Symbol for “THE OPERATION

GUIDE MUST BE READ”

Symbol for “TYPE BF APPLIED 

PARTS”

Symbol for “MANUFACTURER”

Symbol for “ENVIRONMENT 

PROTECTION - Electrical waste

products should not be disposed of

with household waste. Please 

recycle where facilities exist. Check 

with your local authority or retailer 

for recycling advice”

Symbol for “SERIAL NUMBER”

Symbol for “DIRECT CURRENT”

Symbol for “RECYCLE”

Symbol for “MANUFACTURE DATE”

Caution: These notes must be 

observed to prevent any damage 

to the device.

SN

INTRODUCTION

INTRODUCTION

General Description

Measurement Principle

Safety Information

Indications for Use

Contraindications

Thank you for selecting the Pylo PY-802-LTE arm type blood pressure monitor. 

The monitor features blood pressure measurement, pulse rate measurement and digital result 

storage. Readings taken by the PY-802-LTE are equivalent to those obtained by a trained observer 

using the cuff and stethoscope auscultation method. This manual contains important safety and 

care  information, and provides step by step instructions for using the product. 

Please read this manual thoroughly before using the product.

This product uses the Oscillometric Measuring Method to detect blood pressure. 

Before every measurement, the unit establishes a “zero point” equivalent to the atmospheric 

pressure prior to inflating the cuff. Meanwhile, the unit detects pressure oscillation generated by 

beat-to-beat pulsatile, which is used to determine the systolic pressure and diastolic pressure as 

well as pulse rate.

The signs below might be in the user manual, labeling or other components. 

They are the requirement of standard and using.

Features:

 • 78*92mm Digital LCD display

 • Measuring during inflation technology

 • LTE-M wireless communication

The Pylo PY-802-LTE is a digital blood pressure  monitor intended for use in measuring blood 

pressure and heartbeat rate on users with an arm circumference ranging from 22cm to 42cm 

(about 8¾˝-16½˝).

It is intended for adult indoor use only.

1.The device should not be used by any person who is suspected to be or is pregnant .

2.The device is not suitable for use on patients with implanted electrical devices such as cardiac

pacemakers or defibrillators.

3

2

Summary of Contents for PY-802-LTE

Page 1: ...LTE Blood Pressure Monitor PY 802 LTE Thank you for choosing Pylo Health This manual outlines how to use your Pylo blood pressure monitor safely and correctly Please be sure to read it thoroughly and...

Page 2: ...Principle Safety Information LCD Display Signal Components of the Device Included Parts List What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irreg...

Page 3: ...on and provides step by step instructions for using the product Please read this manual thoroughly before using the product This product uses the Oscillometric Measuring Method to detect blood pressur...

Page 4: ...eck that operation of the device does not result in prolonged impairment of patient blood circulation When measurement please avoid compression or restriction of the connection tubing The device canno...

Page 5: ...he device doesn t need to be calibrated within two years of reliable service If you have any problems with this device such as setting up maintaining or using please contact the SERVICE PERSONNEL of P...

Page 6: ...d special power adapter which complies with local safety standard Do not use new and used batteries together Do not use different types of batteries together Do not dispose the batteries in fire Batte...

Page 7: ...in place Don t make it too tight allow a finger to fit between the cuff and your arm 10 If possible relax and rest for at least 5 minutes before taking a measurement 11 Lay your arm on a table with y...

Page 8: ...urn on the monitor The cuff will begin to inflate and the measurement will be taken and saved 2 Once measurement is taken the device will connect to the network and start transmission The symbol will...

Page 9: ...e device In a very cold environment When cleaning device use a lightly moist cloth without soap or detergent After drinking tea coffee or using tobacco products Keep away from water If splashed immedi...

Page 10: ...he person takes medicine the pressure may vary even more 3 Wait at least 3 minutes between measurements What you need to pay attention to when you measure your blood pressure at home If the cuff is ti...

Page 11: ...1 Problem SYMPTOM CHECK THIS REMEDY No power or Low batteries Display will not light up or show Batteries are exhausted Replace with new batteries Batteries are inserted incorrectly Insert the batteri...

Page 12: ...to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential ins...

Page 13: ...rer of medical devices General Requirements for Safety EN 60601 1 2006 A1 2013 IEC 60601 1 2005 A1 2012 Medical electrical equipment Part 1 General requirements for basic safety and essential performa...

Page 14: ...z Conduced RF IEC61000 4 6 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0 15 MHz and 80 MHz 80 AM at 1 kHz 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0 15 MHz and...

Reviews: