INTRODUCTION

INTRODUCTION

5

4

CAUTION

CAUTION

* This device is intended for adult use in homes only.

* The device is not suitable for use on neonatal patients, pregnant women,patients with 

implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial

fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or 

arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior

to using the unit if you suffer from illnesses.

* The device is not suitable for measuring the blood pressure of children. Ask your doctor before

using it on older children.

* The device is not intended for patient transport outside a healthcare facility.

* The device is not intended for public use.

* This device is intended for no-invasive measuring and monitoring of arterial blood pressure.

It is not intended for use on extremities other than the arm or for functions other than obtaining

a blood pressure measurement.

* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood

pressure.Do not begin or end medical treatment without asking a physician for treatment advice.

* If you are taking medication,consult your physician to determine the most appropriate time to

measure your blood pressure. Never change a prescribed medication without consulting your

physician.

* Do not take any therapeutic measures on the basis of a self measurement. Never alter the dose 

of a medicine prescribed by a doctor. Consult your doctor if you have any question about your 

blood pressure.

* When the device is used to measure patients who have common arrhythmias such as atrial or 

ventricular premature beats or atrial fibrillation, the best result may occur with deviation.

Please consult your physician about the result.

* Don’t kink the connection tube during use, otherwise, the cuff pressure may continuously

increase which can prevent blood flow and result in harmful injury to the PATIENT.

* When using this device, please pay attention to the following situation which may interrupt

blood flow and influence blood circulation of the patient, thus cause harmful injury to the 

patient: connection tubing kinking too frequent and consecutive multiple measurements; the 

application of the cuff and its pressurization on any arm where intravascular access or therapy, 

or an arterio-venous (A-V) shunt, is present; inflating the cuff on the side of a mastectomy.

* Warning: Do not apply the cuff over a wound; otherwise it can cause further injury.

*Do not inflate the cuff on the same limb which other monitoring ME equipment is applied

around simultaneously, because this could cause temporary loss of function of those

simultaneously-used monitoring ME equipment.

*On the rare occasion of a fault causing the cuff to remain fully inflated during measurement,

open the cuff immediately. Prolonged high pressure (cuff pressure > 300mmHg or constant

pressure ? 15mmHg for more than 3 minutes) applied to the arm may lead to an ecchymosis.

*Please check that operation of the device does not result in prolonged impairment of patient

blood circulation.

* When measurement, please avoid compression or restriction of the connection tubing.

* The device cannot be used with HF surgical equipment at the same time.

* The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER was clinically

investigated according to the requirements of ISO 81060-2:2013.

* To verify the calibration of the AUTOMATED SPHYGMOMANOMETER, please contact the 

manufacturer.

* This device is contraindicated for any female who may be suspected of, or is pregnant. Besides

providing inaccurate readings, the effects of this device on the fetus are unknown.

* Too frequent and consecutive measurements could cause disturbances in blood circulation and

injuries.

* This unit is not suitable for continuous monitoring during medical emergencies or operations.

Otherwise, the patient’s arm and fingers will become anaesthetic, swollen and even purple due 

to a lack of blood.

* When not in use, store the device in a dry room and protect it against extreme moisture, heat, lint,

dust and direct sunlight. Never place any heavy objects on the storage case.

* This device may be used only for the purpose described in this booklet. The manufacturer cannot 

be held liable for damage caused by incorrect application.

*This device comprises sensitive components and must be treated with caution. Observe the

storage and operating conditions described in this booklet.

* The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable

anesthetic mixture with air of with oxygen or nitrous oxide.

* Warning: No servicing/maintenance while the ME equipment is in use.

* The patient is an intended operator.

* The patient can measure, and charge power under normal circumstances and maintain the

device and its accessories according to the user manual.

* To avoid measurement errors, please avoid the condition of strong electromagnetic field

radiated interference signal or electrical fast transient/burst signal.

* The blood pressure monitor, and the cuff are suitable for use within the patient environment. 

If you are allergic to polyester, nylon or plastic, please don’t use this device.

* During use, the patient will be in contact with the cuff. The materials of the cuff have been

tested and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010.

It will not cause any potential sensation or irritation reaction.

* Adaptor is specified as a part of ME EQUIPMENT.

* If you experience discomfort during a measurement, such as pain in the arm or other complaints, 

press any button to release the air immediately from the cuff. Loosen the cuff and remove it from 

your arm.

* If the cuff pressure reaches 40 kPa (300 mmHg), the unit will automatically deflate. Should the 

cuff not deflate when pressure reaches 40 kPa (300 mmHg), detach the cuff from the arm and 

press any button to stop inflation.

* Before use, make sure the device functions safely and is in proper working condition. 

Check the device, do not use the device if it is damaged in any way. The continuous use of a 

damaged unit may cause injury, improper results, or serious danger.

* Do not wash the cuff in a washing machine or dishwasher!

Summary of Contents for PY-802-LTE

Page 1: ...LTE Blood Pressure Monitor PY 802 LTE Thank you for choosing Pylo Health This manual outlines how to use your Pylo blood pressure monitor safely and correctly Please be sure to read it thoroughly and...

Page 2: ...Principle Safety Information LCD Display Signal Components of the Device Included Parts List What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irreg...

Page 3: ...on and provides step by step instructions for using the product Please read this manual thoroughly before using the product This product uses the Oscillometric Measuring Method to detect blood pressur...

Page 4: ...eck that operation of the device does not result in prolonged impairment of patient blood circulation When measurement please avoid compression or restriction of the connection tubing The device canno...

Page 5: ...he device doesn t need to be calibrated within two years of reliable service If you have any problems with this device such as setting up maintaining or using please contact the SERVICE PERSONNEL of P...

Page 6: ...d special power adapter which complies with local safety standard Do not use new and used batteries together Do not use different types of batteries together Do not dispose the batteries in fire Batte...

Page 7: ...in place Don t make it too tight allow a finger to fit between the cuff and your arm 10 If possible relax and rest for at least 5 minutes before taking a measurement 11 Lay your arm on a table with y...

Page 8: ...urn on the monitor The cuff will begin to inflate and the measurement will be taken and saved 2 Once measurement is taken the device will connect to the network and start transmission The symbol will...

Page 9: ...e device In a very cold environment When cleaning device use a lightly moist cloth without soap or detergent After drinking tea coffee or using tobacco products Keep away from water If splashed immedi...

Page 10: ...he person takes medicine the pressure may vary even more 3 Wait at least 3 minutes between measurements What you need to pay attention to when you measure your blood pressure at home If the cuff is ti...

Page 11: ...1 Problem SYMPTOM CHECK THIS REMEDY No power or Low batteries Display will not light up or show Batteries are exhausted Replace with new batteries Batteries are inserted incorrectly Insert the batteri...

Page 12: ...to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential ins...

Page 13: ...rer of medical devices General Requirements for Safety EN 60601 1 2006 A1 2013 IEC 60601 1 2005 A1 2012 Medical electrical equipment Part 1 General requirements for basic safety and essential performa...

Page 14: ...z Conduced RF IEC61000 4 6 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0 15 MHz and 80 MHz 80 AM at 1 kHz 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0 15 MHz and...

Reviews: