SYMBOL
DESCRIPTION
EXPLANATION
Systolic blood pressure
High pressure result
Diastolic blood pressure
Low pressure result
Pulse
Pulse/minute
Current Time
Time (year:month:day:hour:minute)
Heartbeat
Heartbeat dectetion during measurement
mmHg
Measurement Unit of the blood pressure
Battery Indicator
Indicate the current battery
Irregular heartbeat
Irregular heartbeat
Data transmission indication
Indicates that the data is being sent. oH will
show on screen to indicate success.
Shocking reminder
Sudden movement will result in inaccurate
readings
Signal indication
Indicates the signal situation in the
communication process.
INTRODUCTION
INTRODUCTION
7
6
CAUTION
* The service life of the cuff may vary by the frequency of washing, skin condition, and storage
state. The typical service life is 10000 times.
* It is recommended that the performance should be checked every 2 years and after maintenance
and repair, by retesting at least the requirements in limits of the error of the cuff pressure
indication and air leakage (testing at least at 50mmHg and 200mmHg).
* Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according to the local
guidelines.
* Manufacturer will make available on request circuit diagrams, component part lists, descriptions,
calibration instructions,etc., to assist to service personnel in parts repair.
* The plug/adapter plug pins insulate the device from the main supply. Do not position the device
in a position where it is difficult to disconnect from the supply mains to safely terminate
operation of ME equipment.
* The operator shall not touch output of batteries /adapter and the patient simultaneously.
* Cleaning :Dust environment may affect the performance of the unit. Please use the soft cloth to
clean the whole unit before and after use. Don’t use any abrasive or volatile cleaners.
* The device doesn’t need to be calibrated within two years of reliable service.
* If you have any problems with this device, such as setting up, maintaining or using, please
contact the SERVICE PERSONNEL of Pylo. Don’t open or repair the device by yourself in the
event of malfunctions. The device must only be serviced, repaired and opened by individuals at
authorized sales/service centers.
* Please report to Pylo if any unexpected operation or events occur.
* Keep the unit out of reach of infants, young children or pets to avoid inhalation or swallowing of
small parts. It is dangerous or even fatal.
* Be careful to strangulation due to cables and hoses, particularly due to excessive length.
* At least 30 min required for ME equipment to warm from the minimum storage temperature
between uses until it is ready for intended use. At least 30 min required for ME equipment to cool
from the maximum storage temperature between uses until it is ready for intended use.
* This equipment needs to be installed and put into service in accordance with the information
provided in the ACCOMPANYING DOCUMENTS;
* Wireless communications equipment such as wireless home network devices, mobile phones,
cordless telephones and their base stations, walkie-talkies can affect this equipment and should
be kept at least a distance d away from the equipment. The distance d is calculated by the
MANUFACTURER from the 80MHz to 5.8 GHz column of Table 4 and Table 9 of IEC 60601-1-2:2014,
as appropriate.
* Please use ACCESSORIES and detachable parts specified/ authorised by MANUFACTURER.
Otherwise, it may cause damage to the unit or danger to the user/patients.
* There is no luer lock connectors are used in the construction of tubing, there is a possibility
that they might be inadvertently connected to intravascular fluid systems, allowing air to be
pumped into a blood vessel.
* Please use the device under the environment which is provided in the user manual.
Otherwise, the performance and lifetime of the device will be impacted and reduced.
LCD Display Signal