background image

 

 

 

 
 
SR 

SYSTEM-ELEKTRONIK GmbH 

Eschachstr. 23 

D-78078 Niedereschach 

phone +49 77289268-0 

[email protected]

                     

 
 

 

Seite | 1

 

 

 

 

 

 

SR-Line 

Industry monitors 

 
 
 
 
 
 
 
 

USER MANUAL 

 
 

Booth: 22.12.2022

 

 

 

Reproductions of any kind, even as excerpts, require the written permission of SR System Elektronik GmbH. 

 

ATTENTION: 

This document will not be withdrawn when a new edition is published, all previous 

editions will lose their validity. 

 

 
 

Copyright © 2022 SRLine

 

Summary of Contents for R-FLAT

Page 1: ...1 SR Line Industry monitors USER MANUAL Booth 22 12 2022 Reproductions of any kind even as excerpts require the written permission of SR System Elektronik GmbH ATTENTION This document will not be withdrawn when a new edition is published all previous editions will lose their validity Copyright 2022 SRLine ...

Page 2: ...tion 9 Notes on compliance with the EMC Directive CE mark 10 EMV 10 Model variants 11 VESA DPMS Behavior without video signal 11 Auto signal detection 12 Characteristics 12 VESA mounting 12 Environmental conditions 12 Service OSD 13 Functions and keys 13 Hotkeys 13 OSD Status external LED s 13 OSD Menu Overview 14 Menu Picture 14 Menu Display 14 Menu Color 15 Menu Other 15 Menu Advance 16 Menu Aud...

Page 3: ...8078 Niedereschach phone 49 77289268 0 info sr line com Seite 3 HDMI D24P 24 AC supply 25 DC Plug 12 24 V 25 Grounding bolt 25 IR Remote Control Option 26 Modified Chapter Page Output stand Reason for change 22 12 2022 Creation of this document ...

Page 4: ...instructions must therefore be observed Before working on the open unit any charge on the body must be discharged by touching the grounded housing parts The same applies of course to any protective insulated tools to be used This must also be discharged on a grounded object If you remove or add modules from the system the device must always be switched off or disconnected from the supply voltage Y...

Page 5: ...he device on an unstable surface All slots and openings on the bottom and back of the device are used for ventilation to adequately protect the device from overheating These ventilation slots must never be covered The unit must never be placed near or on a radiator or other heat source The unit must always be connected to a power supply according to the label on the back of the housing Do not inse...

Page 6: ...ntent is preserved Since the video signals from PCs and workstations are not subject to any standardization in terms of timing the image position can be adjusted in all parameters for special variants All necessary adjustments are made via an easy to use OSM menu on screen manager and only have to be made once the selected parameters are saved The monitor is supplied via the integrated wide range ...

Page 7: ...umber of oscillation processes in thousands of oscillations per second Hz Number of oscillation processes in oscillations per second H Sync Indicates the start of transmission of a new line Serves for synchronization between an image source and a receiver V Sync Indicates the start of transmission of a new line Serves for synchronization between an image source and a receiver European Union Declar...

Page 8: ...e the unit in the open state during setup and repair work special care must be taken No conversions may be carried out in this state It cannot be ruled out that this will cause short circuits which will result in damage to various components Due to the manufacturing process it cannot be ruled out that sharp corners and edges may protrude from printed circuit boards and sheet metal parts Please han...

Page 9: ...t the sender immediately Check the scope of delivery against the delivery bill Installation of the device unit The device must not be exposed to excessive cold heat moisture or dirt The ambient conditions specified in the Technical data must be observed to maintain operational safety Before attaching the device to a VESA mount check whether the maximum permissible weight for the mount is observed ...

Page 10: ...to ensure that the entire system complies with the legal regulations Make sure that all devices have an appropriate test mark or manufacturer s declaration The connection to the connected devices must be made via shielded cables Cables with foil shielding are less suitable than cables with braided shielding and a high degree of coverage The connector housing must have an all round connection with ...

Page 11: ...nt codes are added to the product group designation one after the other as required following the sequence of the variant table Only one variant may be used from each area Therefore only the variants with which the respective monitor is equipped are listed in the result 3 Vorgänger 7 Mini Frontblende M 7 High Level Edelstahl V2A V4A Salzwasser etc A A4 8 Low Level RAL 7032 kieselgrau G 4 Multi RAL...

Page 12: ...connected or the video signal is lost connection is disconnected the monitor behaves as described under VESA DPM S This mode can only be restored by turning the power off As long as the monitor is not switched to the power suspend mode the last detected video source returns when the monitor is switched on again image is displayed again Characteristics Supports PC signals from 640x480 to 1920x1200 ...

Page 13: ...ELEKTRONIK GmbH Eschachstr 23 D 78078 Niedereschach phone 49 77289268 0 info sr line com Seite 13 Service OSD All settings are made via theOnScreenDisplay OSD Functions and keys Hotkeys OSD Status external LED s ...

Page 14: ... the BLU backlight level 0 100 Brightness Setting the LCD Brightness 0 100 the LCD Brightness 0 100 Contrast Adjust the image contrast 0 100 Image sharpness Setting the image sharpness 0 4 Menu Display OSD Menu Description Automatische Einstellung Auto Adjustment of LCD Screen image H Position Adjust the Screen Horizontal Position V Position Adjust the Screen Vertical Position Clock Adjust the Ana...

Page 15: ...re 9300 7500 6500 5800 sRGB User Color effect Select the color mode Standard Game Movie Photo Vivid User Demo The user can test the values of the color menu in demo mode Shade Setting the digital color value 0 100 Saturation Setting the digital color value 0 100 OSD Menu Description Rest Function of Reset OSD value Menu time Setting the OSD Menu time OSD H Position Adjust the OSD Menu Position OSD...

Page 16: ...escription Volume Adjust the sound volume 0 100 Mute Mute On Off Audio Source Select the audio source Analog Digital OSD Menu Description Aspect ratio Set display ratio full screen 16 9 4 3 5 4 1 1 User Over Scan Display Over Scan Function only HDMI Video Input DDCI DDCI function enable On Off Ultra Vivid Ultra Vivid Level Off Low Middle High ...

Page 17: ... 23 D 78078 Niedereschach phone 49 77289268 0 info sr line com Seite 17 Hotkey Function Definition Key Description Down Key Check input video information Up Key Select video input Auto DP HDMI RGB DVI Input Video Select Input Video Select ...

Page 18: ... device Do not insert any objects into the device Foreign objects of any kind inserted through the housing can lead to operational safety hazards and cause damage to the device and to persons Do not spill any liquids inside If this should happen however disconnect the device from the power supply immediately There is a risk of fire if operation continues Only install system extensions that are com...

Page 19: ... unit open unit The use of scouring powder and plastic dissolving cleaning cleaning agents is strictly prohibited The interior may only be cleaned by the service technician Before commissioning the device must be completely dry risk of short circuit fire As the surface of LCDs is very soft and easy to scratch please use a soft dry cloth for cleaning and do not use any chemical cleaning agents The ...

Page 20: ...ical A maximum tilt angle of 45 must not be exceeded To be used in the countries of the European Union and other European countries with a separate collection system The marking on the product or on the accompanying literature indicates that it must not be disposed of with other household waste at the end of its working life Please dispose of this device separately from other waste to avoid harmin...

Page 21: ...d 2014 30 EU Applied standards Applied standards Normes appliquées DIN EN 62368 1 2020 A11 2020 DIN EN 55022 AC 2011 DIN EN 61000 6 2 2005 AC 2005 EMV tests were performed with standard cables of cable lengths up to 2 5 meters If longer cables are used then more extensive tests may be required to demonstrate compliance with the EMC Directive 93 68 EWG CE Marking EN 62368 1 Security Only devices th...

Page 22: ...8078 Niedereschach phone 49 77289268 0 info sr line com Seite 22 Appendix Pin assignment VGA 15 pol HD Sub Mini DIN Pin Signal 1 Red 2 Green 3 Blue 4 GND 5 GND 6 GND 7 GND 8 GND 9 Nc 10 GND 11 Nc 12 DDC Data SDA 13 H SYNC 14 V SYNC 15 DDC Clock ...

Page 23: ...SR SYSTEM ELEKTRONIK GmbH Eschachstr 23 D 78078 Niedereschach phone 49 77289268 0 info sr line com Seite 23 DVI D24P DVI D Dual Link ...

Page 24: ...SR SYSTEM ELEKTRONIK GmbH Eschachstr 23 D 78078 Niedereschach phone 49 77289268 0 info sr line com Seite 24 HDMI D24P max 10 m line length DisplayPort DP max 3 m line length ...

Page 25: ...h phone 49 77289268 0 info sr line com Seite 25 AC supply 100 240 V AC IEC Cold appliance socket DC Plug 12 24 V Phoenix MSTB 2 5 2 STF 5 08 Grounding bolt Low voltage ground functional ground For proper function especially in connection with a capacitive touch ...

Page 26: ...SR SYSTEM ELEKTRONIK GmbH Eschachstr 23 D 78078 Niedereschach phone 49 77289268 0 info sr line com Seite 26 IR Remote Control Option ...

Reviews: