18
stabilizes (about 30 seconds).
5. Read the temperature in the display.
Note: The temperature probe is fitted with a type K
mini connector. A mini connector to banana connector
adaptor is supplied for connection to the input banana
jacks.
SPECIFICATIONS
Technical:
Insulation:
Class2, Double insulation.
Overvoltage category:
CATIV 600V,CATIII 1000V
NOTE: These meters meet CAT III and CAT IV IEC 61010
standards. The IEC 61010 safety standard defines four
overvoltage categories (CAT I to IV) based on the magnitude
of danger from transient impulses. CAT III meters are
designed to protect against transients in fixed-equipment
installations at the distribution level; CAT IV meters are
designed to protect against transients from the primary
supply level (overhead or underground utility service).
Maximun voltage between any terminal and earth
ground:
1000V DC/AC RMS