To facilitate lamp removal, ensure there is enough space at the lamp connector end to safely
remove the UV lamp and/or quartz sleeve (See Figure 2).
The controller will require a ground fault circuit interrupter (GFCI or GFI) outlet and should be
mounted beside or above the chamber.
NOTE:
All Puretec UV disinfection systems are intended for indoor use only as they should not
be exposed to the elements.
Installation
INSTALLATION SHOULD BE COMPLETED BY
QUALIFIED TRADESPEOPLE. FAULTY OPERATION
DUE TO UNQUALIFIED PERSONS WILL RESULT IN
VOIDED WARRANTY COVERAGE.
1. The UV chamber can be installed either
horizontally or vertically using the clamps
provided. Vertical installation is the preferred
method with the inlet at the bottom (lamp
connection at the top) as it allows any air that
may be in the lines to be easily purged from the
system.
2. The use of a by-pass assembly is recommended
as it will allow you to isolate the UV chamber. This
will allow for easier access in case maintenance is
required (See Figure 5).
3. Use the supplied fasteners to mount the UV
chamber to wood or drywall. If mounting to an
alternate material you will need to purchase the
proper corresponding fasteners.
4. For water supplies where the maximum flow rate
is unknown, a flow restrictor is recommended
so that the rated flow of your particular Puretec
system is not exceeded. The flow restrictor should
be installed on the inlet port of the UV chamber.
Fig. 4 - Lamp
Removal Spacing
Leave at least
an additional
chamber length
to facilitate
lamp and sleeve
removal.