11
Puretec Radfire RI Series
Copyright © Puretec Pty Ltd 2021
13. Plug the lamp connector into the lamp. Note the
keying for proper alignment (see Figure 10a,
10b).
Insert the lamp connector into the gland nut and
turn the connector approximately ¼ turn to lock
the connector to the gland nut as in Figure 11.
14. Tighten the captive ground screw to the ground
lug on the UV chamber to ensure proper
grounding.
15. Your system is now ready to be plugged into the
appropriate GFCI protected outlet. Refer to the
following section before any water is allowed to
flow through the system.
System Disinfection
With a new installation, or any time the UV system is shut down for service, without power, or
is in-operative for any other reason, the lines in the home or facility could be contaminated.
Use the following steps to fully disinfect the lines throughout the entire home or facility.
1. Check for and remove any “dead ends” in the lines throughout the home as these can
harbor bacteria. Plug in the UV system and wait until it is ready for operation.
2. Remove the filter cartridge from the last sump and fill it with 1-2 cups of Puretec
TankSafe
™
. Replace the sump and slowly turn on the water supply.
3. At a water outlet, run the water. Repeat this for all faucets, toilets, shower heads,
Fig. 10a - Standard Output
UV Lamp Connection
Fig. 10b - High Output UV
Lamp Connection
Fig. 11 - Lamp Connector
Fig. 12 - Ground Screw
Connection
System Disinfection