Lamp Countdown Sequence
The system counts down the number of days until a lamp change is required.
At thirty days remaining, the screen will change to a yellow caution indicator. At seven days
remaining, the system will additionally repeat an audible chirp. Past the zero day threshold,
the screen changes to solid red with a continuous buzzer.
The audible chirp or alarm can be deferred for seven days by holding the controller button
down for a period of five seconds. The number of deferrals used will be displayed as below.
Once the deferral expires, the alarm will sound once again. The deferral can be repeated up to
three times.
NOTE:
At any point after lamp expiration, the water may be unsafe for consumption and
should not be consumed without another form of disinfection.