VIP-NET-M28A Network Switch - USER MANUAL
VERSION 1.0
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server/Client
DHCP Relay
Modbus TCP
SMTP Client
SNTP Server
Network Redundancy
O-Ring
O-Chain
MRP
MSTP (RSTP/STP compatible)
RS-232 Serial Console
Port
RS-232 in RJ-45 connector with console cable. 115200bps, 8, N, 1
LED Indicators
Power Indicator (PWR)
Green: Indicates that the system ready. The LED is blinking when the
system is upgrading firmware
Power Indicator (PWR1
/ PWR2)
Green: Power LED x 2
Ring Master Indicator
(R.M.)
Green: Indicates that the system is operating in O-Ring Master mode
O-Ring Indicator
(Ring)
Green: Indicates that the system operating in O-Ring mode
Green Blinking: Indicates that the Ring is broken.
Fault Indicator (Fault)
Amber: Indicate unexpected event occurred
Reset To Default
Running Indicator
(DEF)
Green: System resets to default configuration
Supervisor Login
Indicator (RMT)
Green: System is accessed remotely
Smart LED Display
system
Link/Act(LK/ACT) / Speed(SPD) / Duplex(FDX) / Remote (RMT) green LED
indicator x 4
Mode select Button (MODE) : Link/Act(LK/ACT) / Speed(SPD) / Duplex(FDX)
/ Remote (RMT) mode select button Port 1 ~ 28 Link/Act(LK/ACT) LED show
: Green x 28
Fault Contact
Relay
Relay output to carry capacity of 1A at 24VDC
Power
Redundant power input
modular
Dual 100~240VAC / 100~370VDC power
inputs at terminal block
Power Consumption
(Typ.)
43.5Watts max.
Summary of Contents for PureLink VIP-NET-M28A Media Hub
Page 30: ...VIP NET M28A Network Switch USER MANUAL VERSION 1 0...
Page 35: ...VIP NET M28A Network Switch USER MANUAL VERSION 1 0...
Page 89: ...VIP NET M28A Network Switch USER MANUAL VERSION 1 0...
Page 98: ...VIP NET M28A Network Switch USER MANUAL VERSION 1 0 SNMP Trap...
Page 173: ...VIP NET M28A Network Switch USER MANUAL VERSION 1 0...