Page 9
air gap depending on local, state or federal guidelines.
12.
This is the distiller. On page 8, all of the main components in the
distiller are identified and explained.
13.
The inlet solenoid automatically allows raw water into the distiller.
14.
This boiling chamber heats the raw water until it changes to steam.
15.
These are the high and low level probes that control the level in the
boiling chamber.
16.
The distilled water enters the storage tank here.
17.
The distilled water storage tank.
18.
High, Medium and low level floats for the distilled water storage tank.
19.
This pump, with built-in pressure switch, delivers pressurized water to
remote locations.
20.
The carbon filter is mounted inside the housing. This filter should be
changed every 3 months or 90 days.
21.
This enclosure houses all of the electronic controls for the entire distilla-
tion unit. This housing should only be opened by a Pure Water, Inc.
certified service person.
22.
This automatic valve drains the boiling chamber periodically to reduce
buildup of scale and contaminants in the boiling chamber.