Page 19
the electrical enclosure.
e) remove the drain tubing from the drain solenoid. Lift the Boiling chamber out of the
distiller tray.
f)
Put the boiling chamber in the sink. Remove the lid.
g) Dump the boiling chamber until the water level is 2 inches above the heating ele-
ment. Connect the heating element directly to a 120V electrical outlet using the
appropriate cord. Watch for signs that the heating element is starting to heat the
water. Allow the water to come to a boil for about 2 minutes. This shows that the
heating element is operating normally. If the heating element does not function, the
heating element or heating element controller requires replacement.
h) If the water in the boiling chamber becomes hot, but does not boil, then the boiling
chamber needs to be descaled. (Refer to page 15 for instructions.)
i)
Replace and reinstall the boiling chamber into the distiller tray. Connect all tubes and
wires.