Page
3
Functional Description
Ultra 5
sends a transmit pulse to the transducer, which emits an ultrasonic
pulse perpendicular to the transducer face, and the returned echo is sent back
to the
Ultra 5
. The time taken to receive the echo is measured and the
distance from the transducer face to the surface being monitored is
calculated.
Ultra 5
can measure from zero to 40m from the face of the transducer to the
surface being monitored, dependent on the application chosen and
transducer used.
The relays can be programmed to activate alarms, pump starters, or other
control equipment. There is an isolated 4-20 mA output that can be
connected to a recorder or PLC, to monitor, depending on application
chosen,
level
space
or
distance, OCM head, OCM flow or volume,
independently from that shown on the display. There is an RS232 port, so
that the
Ultra 5
can be operated remotely by a PC or other equipment.
Ultra 5
can be programmed either by the built-in keypad (standard on all
wall and fascia units), or by PC via the RS 232 Serial Interface (optional).
The optional rack and panel mounted units are programmed with the
“Remote Communicator”, and one Communicator can program many Pulsar
Ultra 5
units. All parameters are stored in non-volatile memory, so are
retained in the event of power interruption. A second backup copy of all
parameters can also be retained in the
Ultra 5
memory, in case an alternative
set of parameters needs to be stored.
Five user definable control relays with individual setpoints and intelligent
performance logging software features ensure maximum control versatility.
The system utilises the unique DATEM software (
D
igital
A
daptive
T
racking of
E
cho
M
ovement). This is a proven digital mapping technique
developed especially for the Pulsar
Ultra
range, which gives the system
unequalled ability when identifying the “true target level” in the face of
competing echoes from pipes, pumps or other obstructions. Coupled with
the powerful, long-range abilities of the ‘all new’ dB transducer range, the
Ultra 5
lives up to its reputation as the most reliable ultrasonic level
measurement system available.
The Pulsar
Ultra 5
ultrasonic level controller has been designed to provide
maintenance-free fit and forget performance.
Summary of Contents for ULTRA 5
Page 1: ...ULTRA 5 INSTRUCTION MANUAL ...
Page 2: ......
Page 4: ......
Page 15: ...Page 7 EU Declaration of Conformity Wall Mount ...
Page 16: ...Page 8 Fascia Mount ...
Page 17: ...Page 9 Rack and Panel ...
Page 18: ...Page 10 This page left blank intentionally ...
Page 21: ...Page 13 The full dimensions of the enclosure are as shown below ...
Page 23: ...Page 15 The full dimensions of the Fascia mount enclosure are as shown below ...
Page 35: ...Page 27 This page left blank intentionally ...
Page 151: ...Page 143 This page left blank intentionally ...
Page 240: ...Page 232 This page left blank intentionally ...