![Pulsar KRYPTON FXG50 User Manual Download Page 5](http://html1.mh-extra.com/html/pulsar/krypton-fxg50/krypton-fxg50_user-manual_1624483005.webp)
5
USER MANUAL FOR
KRYPTON XG50
THERMAL IMAGING MONOCULAR
Attention!
When the indicator of the charger is continuously red upon battery installation, the battery charge
level is probably lower than acceptable (the battery has been in deep discharge for too long). In this case:
द
Connect the charger with the battery inserted to the mains and leave it for a long time (up to several hours)
to charge.
द
Remove the battery from the charger and then re-insert it into the charger.
द
If the indicator starts blinking green, the battery is fault free.
द
If the indicator stays on red, the battery is faulty. Do not use the battery!
INSTALLING BATTERY PACK
•
Lower the lever
(4)
.
•
Remove the protective cover of the battery compartment
(3)
.
•
Remove the Battery
(5)
from the Charger.
•
Insert the Battery
(5)
into the slot on the device body specially
designed for it so that the element D (a ridge on the Battery
body) is facing downwards.
•
Lock the Battery
(5)
by lifting the lever
(4)
.
PRECAUTIONS
•
Always use the IPS charger supplied with the device (or
purchased separately) to charge IPS batteries. Using the
unsuitable charger can cause irreparable damage to the battery
and fire.
•
Do not charge the battery immediately after brining it from cold to warm. Wait at least 30 minutes for the
battery to warm up.
•
Do not leave the battery unattended while charging.
•
Do not use the charger if it has been modified or damaged.
•
Do not leave the battery in a charger connected to the network after charging is complete.
•
Do not expose the battery to high temperatures and naked flame.
•
Do not use the battery as a power source for devices that do not support IPS7 batteries.
•
Do not disassemble or deform the battery.
•
Do not drop or strike the battery.
•
Do not submerge the battery.
•
Keep the battery out of the reach of children.
Attention!
Please do not use the IPS 14 Battery Pack with the KRYPTON XG50 due to battery´s heavy weight.
RECOMMENDATIONS FOR USE
•
The battery should be partially charged for long-term storage – 50 to 80 %.
•
The battery should be charged at an ambient temperature of 0°C…+35°C (+32°F…+95°F). Otherwise, lifespan of
the battery will decrease significantly.
•
When using the battery at sub-zero temperatures, the battery capacity decreases, this is normal and not a
defect.
•
Do not use the battery at temperatures outside the range of -25 °С...+50 °С (-13°F…+122°F) – this may reduce
battery’s life.
•
The battery has a short-circuit protection. However, any situation that may cause short-circuiting should be
avoided.
EXTERNAL POWER SUPPLY
External power is supplied from an external source, such as a 5V Power Bank.
•
Attach the external power source to the device's USB connector
(11)
.
•
The device will switch to operation from the external power source, while the IPS7 battery will be gradually
recharged.
•
An icon of a battery
will appear on the display showing its charge as a percentage.
•
If the device is operated from an external power source and the IPS7 battery is not connected, an icon is
displayed
.
•
When the external power supply is disconnected, the device switches to the internal power supply without
the device powering off.
Attention!
Charging Power Bank IPS7 batteries at air temperatures below 0 °C can result in reduced battery
life. When using external power, connect Power Bank to the switched-on device, which have worked for several
minutes.
OPERATION
ATTENTION!
The lens of the device must not be pointed at any sources of intense energy, such as laser-emitting
devices or the sun. This may damage the electronic components in the device. Damage caused by failure to
comply with the operating guidelines is not covered under warranty.
INSTALLING THERMAL IMAGING MODULE ON THE OPTICAL DEVICE
•
Remove the eyepiece cover
(2)
.
•
Select the Ring Adapter
(15)
(sold separately) with the insert
(14)
of the desired diameter depending on the
outer diameter of the lens of your optical device
(13)
(see table). The designation 42 mm / 50 mm / 56 mm in
the name of the adapter means the lens diameter of the optical device.
Selection table for optical device inserts
Ring Adapter model
The internal diameter of the insert needs to match the outer diameter
of the objective lens housing of the daylight optical device it is being
installed on.
Insert internal diameter, mm
Suitable for lens housing of
daylight optical devices with an
outer diameter of, mm
PSP Ring Adapter 42 mm
45.5
45.5
46
46
46.5
46.5
47
46.7-47.6
48
47.7- 48.6
49
48.7-49.6
50
49.7-50.6
PSP Ring Adapter 50 mm
51.6
51.6
53.4
53.4
55
54.7-55.6
56
55.7-56.6
57
56.7-57.6
58
57.7-58.6
59
58.7-59.6
5
D
4
3